Inspections for the day of: Wednesday, October 19, 2016.
Number of inspections: 40
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-00840 BLD-Final10/18/201610/19/201610/19/2016 4:47:36 PMPPASS
Dave Phone #: ###-####
BLD16-00840 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:47:30 PMPPASS
BLD16-00839 BLD-Final10/18/201610/19/201610/19/2016 4:47:23 PMPPASS
Dave Phone #: ###-####
BLD16-00839 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:47:18 PMPPASS
BLD16-00838 BLD-Final10/18/201610/19/201610/19/2016 4:47:12 PMPPASS
Dave Phone #: ###-####
BLD16-00838 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:47:06 PMPPASS
BLD16-00198 BLD-Final10/18/201610/19/201610/19/2016 4:46:58 PMPPASS
Dave Phone #: ###-####
BLD16-00198 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:46:53 PMPPASS
BLD16-00847 BLD-Final10/18/201610/19/201610/19/2016 4:46:35 PMPPASS
Dave Phone #: ###-####
BLD16-00847 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:46:30 PMPPASS
BLD16-00837 BLD-Final10/18/201610/19/201610/19/2016 4:46:10 PMPPASS
Dave Phone #: ###-####
BLD16-00837 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:46:05 PMPPASS
BLD16-00844 BLD-Final10/18/201610/19/201610/19/2016 4:45:57 PMPPASS
Dave Phone #: ###-####
BLD16-00844 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:45:52 PMPPASS
BLD16-00846 BLD-Final10/18/201610/19/201610/19/2016 4:45:43 PMPPASS
Dave Phone #: ###-####
BLD16-00846 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:45:37 PMPPASS
BLD16-00845 BLD-Final10/18/201610/19/201610/19/2016 4:45:30 PMPPASS
Dave Phone #: ###-####
BLD16-00845 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:45:24 PMPPASS
BLD16-00843 BLD-Final10/18/201610/19/201610/19/2016 4:45:17 PMPPASS
Dave Phone #: ###-####
BLD16-00843 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:45:12 PMPPASS
BLD16-00842 BLD-Final10/18/201610/19/201610/19/2016 4:45:03 PMPPASS
Dave Phone #: ###-####
BLD16-00842 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:44:57 PMPPASS
BLD16-00841 BLD-Final10/18/201610/19/201610/19/2016 4:44:39 PMPPASS
Dave Phone #: ###-####
BLD16-00841 DOC - Permit Finaled10/19/201610/19/201610/19/2016 4:44:26 PMPPASS
BLD15-04407 BLD-Other10/18/201610/19/201610/19/2016 4:43:46 PMAPART
Before 10AM - railings and ceiling inspection - Ed Phone #: ###-####. All issues regarding the handrails have been resolved. Aslo inspected soffitt framing above grid. Noted the framing has not been done in accordance with city approved plans. After speaking with contractor, it was noted that work either needs to be corrected or a letter from the engineer of record accepting the in place work. Main area of concern is new soffit has been supported from the bottom chords of the existing roof trusses. Engineer to justify that the bottom chords can support the additional wieght.
BLD15-04521 BLD-Final10/18/201610/19/201610/19/2016 4:19:38 PMAPART
Mark Phone #: ###-####. OK for temp occ. Needs to provide ADA compliant door hardware on restrooms, provide flusher on turning side in womens restroom, and install boots underneath the lavs. The door hardware on door between showroom and warehouse can be left as installed. Needs to provide code compliant door hardware to exit frfom vestibule doors to exterior without the use of key or special hardware.
MIS16-00186 DOC - Permit Finaled10/19/201610/19/201610/19/2016 3:17:15 PMPPASS
BLD16-02905 BLD-Framing/Rough-in10/18/201610/19/201610/19/2016 3:14:30 PMPPASS
Please call Tom 1/2 hr before. Phone #: ###-#### Inspection requested via web by Jared Waggoner. Interior steel stud walls only ok.
BLD16-03312 BLD-Footing10/19/201610/19/201610/19/2016 2:36:46 PMPPASS
Julentio Phone #: ###-####
BLD16-03309 BLD-Framing/Rough-in10/19/201610/19/201610/19/2016 2:19:01 PMPNH
Steve Phone #: ###-####. no one home and no access, gate locked. Called and left message for Steve.
BLD16-02386 BLD-Final10/19/201610/19/201610/19/2016 1:41:27 PMPFAIL
Manufactured Home final. Please call to meet. ###-#### Phone #: ###-#### Inspection requested via web by Ashleigh Meligan. Provide code compliant stairs on west side.
BLD16-02387 BLD-Final10/19/201610/19/201610/19/2016 1:40:30 PMPNR
Manufactured Home final. Please call to meet ###-#### Phone #: ###-#### Inspection requested via web by Ashleigh Meligan. Needs electrical final.
BLD16-02390 BLD-Final10/19/201610/19/201610/19/2016 1:39:54 PMPNR
Manufacture home final. Please call to meet ###-#### Phone #: ###-#### Inspection requested via web by Ashleigh Meligan. Needs electrical final.
BLD16-02391 BLD-Final10/19/201610/19/201610/19/2016 1:39:09 PMPNR
Manufactured Home final. Please call to meet ###-#### Phone #: ###-#### Inspection requested via web by Ashleigh Meligan. North stair non code compliant.
BLD16-03242 BLD-Footing10/18/201610/19/201610/19/2016 11:31:02 AMADEFR
Phone #: ###-#### Inspection requested via web by Todd Landvatter. Concrete placed when arrived on site. reinforcement was inspected by special inspection.
BLD16-03818 BLD-Final10/18/201610/19/201610/19/2016 10:53:29 AMANR
Steve Phone #: ###-####. Life/safety failed.
BLD15-04399 BLD-Conference10/18/201610/19/201610/19/2016 9:14:13 AMADONE
sign final Phone #: ###-#### Inspection requested via web by Tom Noeker
BLD15-04399 DOC - Permit Finaled10/19/201610/19/201610/19/2016 9:14:06 AMPPASS
BLD15-03590 BLD-Conference10/18/201610/19/201610/19/2016 9:12:26 AMADONE
sign final Phone #: ###-#### Inspection requested via web by Tom Noeker
BLD15-03590 DOC - Permit Finaled10/19/201610/19/201610/19/2016 9:11:50 AMPPASS