ELE17-02099
| Electrical Rough-In | 11/13/2017 | 11/13/2017 | 11/13/2017 2:48:21 PM | P | FAIL |
|
|
Harlan Phone #: ###-#### 110.27(A)(4)(a)- Electrical equipment located below 8' from floor shall be protected from physical damage. All wiring located below 8'. 250.148- All equipment grounding conductors located in a box shall be connected together by approved means. 2 gang by man door. 352.30- PVC shall be secured in place with in 3' of a box or conduit body. Secure below house service and garage panel.
|
ELE16-00391
| Final | 11/7/2017 | 11/13/2017 | 11/13/2017 12:09:29 PM | A | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE16-00391
| Electrical Rough-In | 11/13/2017 | 11/13/2017 | 11/13/2017 12:09:22 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing confirmed rough in ok
|
ELE17-01549
| Electrical Rough-In | 11/9/2017 | 11/13/2017 | 11/13/2017 11:20:11 AM | A | PASS |
|
|
Fiber optics. Main st. Shane is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Area noted from capitol to ramp on main rough in ok cover
|
ELE17-03446
| Electrical Rough-In | 11/9/2017 | 11/13/2017 | 11/13/2017 10:58:38 AM | A | PASS |
|
|
David Forbes ###-#### {CEILING} Phone #: ###-#### Inspection requested via web by Samatha Solberg Grid rough in ok cover
|
ELE17-03712
| Temporary Service | 11/10/2017 | 11/13/2017 | 11/13/2017 9:52:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE17-03564
| Rough-In Permanent Service | 11/10/2017 | 11/13/2017 | 11/13/2017 9:26:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE17-03565
| Rough-In Permanent Service | 11/10/2017 | 11/13/2017 | 11/13/2017 9:03:13 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE17-03789
| Temporary Service | 11/9/2017 | 11/13/2017 | 11/13/2017 8:34:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tracy Robertson t/s u/g n ok
|
ELE16-00360
| Final | 11/7/2017 | 11/13/2017 | 11/13/2017 8:25:08 AM | A | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE16-00360
| Electrical Rough-In | 11/13/2017 | 11/13/2017 | 11/13/2017 8:25:01 AM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing and disconnecting means confirmed. Rough in ok
|