Inspections for the day of: Monday, February 3, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01386 ELE-Aging Inspection2/3/20202/3/20202/5/2020 11:10:21 AM DONE
No activity on permit. Contractor is aware of the need to final aging permits.
ELE19-03595 Electrical Rough-In1/28/20202/3/20202/3/2020 2:11:02 PMPCANC
Inspection to reconnect power Phone #: ###-#### Inspection requested via web by BRS Permitting
ELE19-03595 Permanent Service2/3/20202/3/20202/3/2020 2:07:51 PMPFAIL
Inspection to reconnect power Phone #: ###-#### Inspection requested via web by BRS Permitting Discription doesnt match job. Meter is in place No reconnection needed. No answer at contact number
ELE20-00307 Electrical Rough-In2/3/20202/3/20202/3/2020 1:53:24 PMPNH
Phone #: ###-#### Inspection requested via web by Tyler Ridley
ELE19-02932 Final2/3/20202/3/20202/3/2020 1:52:07 PMPPASS
garage code 1905 Phone #: ###-#### Inspection requested via web by kevin blackmon corrections made final ok
ELE20-00388 Temporary Service2/2/20202/3/20202/3/2020 1:34:48 PMPPASS
greetings
looking for an ok to energize temp power pole any issues or questions please call thank you
have a great day Phone #: ###-#### Inspection requested via web by leon ramirez t/s u/g n ok
ELE19-04947 Electrical Rough-In2/3/20202/3/20202/3/2020 1:06:07 PMPPEND
bracing has been done Phone #: ###-#### Inspection requested via web by dennis mcneely Wire running through holes in trusses have been moved and truss repair has ben done. Electrical rough in ok pending building inspection
ELE20-00027 Electrical Rough-In2/3/20202/3/20202/3/2020 1:05:42 PMPPEND
bracing has been done Phone #: ###-#### Inspection requested via web by dennis mcneely Wire running through holes in trusses have been moved and truss repair has ben done. Electrical rough in ok pending building inspection
ELE19-04158 Final2/3/20202/3/20202/3/2020 12:29:53 PMPPASS
garage code 7750, key for house inside exterior outlet by front door Phone #: ###-#### Inspection requested via web by Robert Schroder Corrections made Final ok
ELE20-00353 Final2/2/20202/3/20202/3/2020 10:37:24 AMAFAIL
Phone #: ###-#### Inspection requested via web by Dave Brueggemann 300.5 Conduits shall be burried 18in deep. 356.12(1) LFMC shall not be used where exposed to physical damage.
ELE20-00214 Temporary Service1/31/20202/3/20202/3/2020 10:33:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE20-00188 Final1/31/20202/3/20202/3/2020 9:41:12 AMAFAIL
Please inspect is there As early as possible please call ###-#### so he can arrive and open the door if needed Phone #: ###-#### Inspection requested via web by shane miller 440.22C Overcurrent shall not exceed manufacturer ratings. (25A max 30A installed Minnimum circuit ampacity is 23.8A. 25A breaker or fuses must be installed)
ELE20-00280 Rough-In Permanent Service2/3/20202/3/20202/3/2020 9:35:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard rough in ok p/s u/g n ok
ELE19-04791 Electrical Rough-In1/30/20202/3/20202/3/2020 8:42:51 AMAPASS
Ron. Secondary contact Nick ###-#### Phone #: ###-#### center wall only ok to cover
ELE19-00964 Final1/31/20202/3/20202/3/2020 8:03:40 AMAPASS
Phone #: ###-#### Inspection requested via web by chris hopkins...rescheduled do to time constraints and lack of inspectors Final ok
ELE19-00964 Electrical Rough-In2/3/20202/3/20202/3/2020 8:03:29 AMAPASS
Phone #: ###-#### Inspection requested via web by chris hopkins...rescheduled do to time constraints and lack of inspectors Rough in ok