ESC19-00303
| General Inspection | 3/11/2020 | 3/11/2020 | | P | |
|
|
|
MIS20-00070
| ESC-Conference | 3/4/2020 | 3/18/2020 | 3/24/2020 4:18:13 PM | P | PEND |
|
|
Corrective actions have been intiated at site: - Perimeter sediment control wattle installed along Curling as requested. - Placed wattle to slow down runoff on the roof access road. - No loose dirt on sidewalk or parking area - Owner Jon states hillside has been seeded as requested.
Notified Jon that the wattle placement and clean up was good, but the wattles need to be trenched into the ground so water does not flow under them.
Will check vegetation establishment and wattle trenching in 2 weeks.
|
ESC18-01280
| Site Final | 3/17/2020 | 3/18/2020 | 3/23/2020 4:14:57 PM | P | NR |
|
|
Stockpile and disturbed area within site. Driveway is complete. No trackout or material leaving site. Will continue to monitor, no corrections requested at this time
|
ESC19-00574
| General Inspection | 3/18/2020 | 3/18/2020 | 3/20/2020 1:33:22 PM | | PASS |
|
|
Update from RP Dustin. Outlet from dewatering has had a screen bar placed to capture floating algae. The basin was also cleaned out and algae removed to prevent discharge to the pond.
RP states that the clean up measures worked and there is significantly less algal build-up and they will continue to maintain the basin as needed.
|
ESC19-01505
| BMP Violation | 3/18/2020 | 3/18/2020 | 3/20/2020 12:17:41 PM | P | PASS |
|
|
stockpile stored in road with ACHD permit and no BMPs
Site cleaned up. No further requests
|
ESC19-00557
| General Inspection | 3/18/2020 | 3/18/2020 | 3/18/2020 12:14:15 PM | | PASS |
|
|
WIP in backyard. No offsite discharges or trackout
|
ESC19-00542
| General Inspection | 3/18/2020 | 3/18/2020 | 3/18/2020 8:11:05 AM | | CANC |
|
|
see ESC19-00525
|
ESC19-00525
| General Inspection | 3/18/2020 | 3/18/2020 | 3/18/2020 8:10:44 AM | | CANC |
|
|
see ESC19-00525
|