Inspections for the day of: Wednesday, April 10, 2019.
Number of inspections: 21
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00085 Site Final4/4/20194/5/2019 A 
ESC18-01021 BMP Violation4/8/20194/10/20194/17/2019 2:37:03 PMAPART
follow up on corrections

- trash around site picked up
- silt fence repaired
- sidwalk cleaned and front row of gatorguard has been maintained.

Corretions needed:
- scoop up left over stucco waste on adjacent lot
- fix erosion on north side of home due to rooftop runoff without gutters.
- clean up sediment/mud on other side of silt fence.
ESC18-00783 General Inspection4/10/20194/10/20194/16/2019 5:53:36 PMPPASS
ESC18-01244 Stop Work Order4/10/20194/10/20194/15/2019 5:00:02 PMAFAIL
SWO posted due uncompleted corrections. RP notified.
ESC18-01452 Site Preparation4/9/20194/10/20194/15/2019 3:53:19 PMAPASS
ESC18-00429 General Inspection4/10/20194/10/20194/12/2019 12:00:32 PM CANC
ESC18-00692 Conference4/10/20194/10/20194/11/2019 12:30:43 PMPDONE
Conducted with RP Cecil. Stone cutting operation getting slurry into gutter. Drains to storm drain around the corner at Fort and 9th.

-Request to clean up staging and material storage.
- Make designated cutting area surrounded by berm.
- Collect slurry water for settling in a container
- Clean gutter after each day
- Remove materials no longer need.
- Cover area with tarp or pop up tent.
ESC18-00993 DOC - Permit Finaled4/10/20194/10/20194/10/2019 11:02:27 PMPPASS
ESC18-00995 Site Final4/10/20194/10/20194/10/2019 11:02:01 PMPPASS
ESC17-01731 Site Final4/10/20194/10/20194/10/2019 4:36:00 PMPPASS
Temporary BMps to remain installed for project next door. See ESC18-01529
ESC18-01244 BMP Violation4/10/20194/10/20194/10/2019 12:30:58 PMPFAIL
Multiple violations:
- overflowing trash
- uncontained/cleaned up stucco washout causing runoff to have high pH
- dirt on sidewalk and gutter.
- gatorguards at bottom corner of lot need to be scooped out.
- finish securing/improving and extending the roof top water conveyance to the street. Erosion occuring in between tarp lining and gatorguard.

Multiple requests have been issued. This site has not passed an ESC inspection since February.

NOV and fines issued.
ESC18-00692 BMP Violation4/10/20194/10/20194/10/2019 11:31:01 AMPFAIL
Dirty stagy and work area. Gutter drains to storm drain inlet on 9th Street, no inlet protection.

pH of murky stone cutting water is 10.4, should not be higher than 9th.

Need to remove or cover all materials. Clean up staging area. Install inlet protection. Clean up mud and sand in gutter. Suck up water pooling in gutter and place in containment for evaporation or disposal.
ESC18-00655 Aging Inspection4/10/20194/10/20194/10/2019 8:09:34 AM CANC
ESC18-00449 Aging Inspection4/10/20194/10/20194/10/2019 8:07:10 AM CANC
ESC16-01395 General Inspection4/10/20194/10/20194/10/2019 8:05:01 AM CANC
ESC18-00462 General Inspection4/10/20194/10/20194/10/2019 8:04:55 AM CANC
ESC17-00455 General Inspection4/10/20194/10/20194/10/2019 8:04:29 AM CANC
ESC18-00467 General Inspection4/10/20194/10/20194/10/2019 8:04:22 AM CANC
ESC18-00651 General Inspection4/10/20194/10/20194/10/2019 8:03:35 AM CANC
ESC18-00600 Aging Inspection4/10/20194/10/20194/10/2019 8:03:14 AM CANC
ESC18-00600 DOC - Permit Finaled4/10/20194/10/20194/10/2019 8:03:10 AMPPASS