Inspections for the day of: Friday, April 19, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01603 Pressure Test4/19/20194/19/20194/19/2019 3:12:06 PMPFAIL
please call ahead of time ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 60lb test failed at 20psi- 20lb gas fail gauge at 10psi
MEC19-00203 Final4/19/20194/19/20194/19/2019 2:50:56 PMPPASS
BJ Phone #: ###-####- final ok
MEC19-01484 Rough-in4/18/20194/19/20194/19/2019 2:23:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- missing seal on supply boot in floor master bedroom
MEC19-01484 Pressure Test4/18/20194/19/20194/19/2019 2:22:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location- 5lb flue test pass
MEC19-01566 Rough-in4/18/20194/19/20194/19/2019 2:00:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Eric Sonner- R/I ok
MEC19-01613 Pressure Test4/19/20194/19/20194/19/2019 1:34:09 PMPFAIL
Under test Phone #: ###-#### Inspection requested via web by Michael Webb- 20lb gas test pass- need yellow tracer wire not painted- need pvc sleeves around risers if poured in concrete- piping to not be covered- one piece does not maintain 12" below grade
MEC19-01559 Final4/19/20194/19/20194/19/2019 1:21:06 PMPNH
meet homeowner at 100pm- unit #21- no one home- no access
MEC19-01610 Pressure Test4/19/20194/19/20194/19/2019 12:55:14 PMPPASS
Just a gas line pressure test witness for a unit heater. Super simple. Phone #: ###-#### Inspection requested via web by Heath Taylor- 20lb gas pass- tagged gas line
MEC19-01610 Rough-in4/19/20194/19/20194/19/2019 12:54:42 PMPFAIL
Just a gas line pressure test witness for a unit heater. Super simple. Phone #: ###-#### Inspection requested via web by Heath Taylor- need csst approved nail plates from manufacture at top plate and fire blocking in wall- need inert tape on penetration thru building wall- whos doing unit heater install?- drip leg on gas line needs to be after shtoff valve and between appliance- b vent doesnt have 1" clearance at roof and needs an insulation shield installed- unit heater needs added to this permit if you did work
MEC19-01488 Final4/19/20194/19/20194/19/2019 11:12:22 AMAPASS
MEC19-01488 Pressure Test4/12/20194/19/20194/19/2019 11:11:13 AMAPASS
Please call Thomas (###-####) 30 minutes prior to showing up, Thank you Phone #: ###-#### Inspection requested via web by Tyler Collado- 20lb gas pass
MEC19-01378 Rough-in4/18/20194/19/20194/19/2019 10:31:53 AMAPASS
PLEASE RE-INSPECT Phone #: ###-#### Inspection requested via web by Oleg Chervak- HVAC and firepace R/I ok
MEC19-01559 Final4/17/20194/19/20194/19/2019 9:50:25 AMACANC
First thing morning would work great for the homeowner. Phone #: ###-#### Inspection requested via web by Kim Evans- i rescheduled this as an afternoon inspection to meet at 100pm
MEC19-01553 Final4/17/20194/19/20194/19/2019 9:49:48 AMPCANC
INSTALLER BRANDAN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC19-01599 Pressure Test4/18/20194/19/20194/19/2019 9:42:56 AMAPASS
please call BJ (homeowner) for access - ###-#### Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass from crawl to underground to firepit location- ok to backfill
MEC19-01599 Final4/19/20194/19/20194/19/2019 9:41:13 AMAPASS
please call BJ (homeowner) for access - ###-#### Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-00452 Conference4/18/20194/19/20194/19/2019 9:31:49 AMAFAIL
10am Duct Blast Phone #: ###-#### Inspection requested via web by Debbie Marino- duct blast test failed- reschedule when fixed
MEC19-01319 Final4/19/20194/19/20194/19/2019 8:41:01 AMAPASS
furnace a/c coil co ok
MEC19-00744 Final4/16/20194/19/20194/19/2019 8:39:57 AMAPASS
830-900 am- ###-####- furnace ac coil co ok
MEC19-01425 Final4/19/20194/19/20194/19/2019 8:27:08 AMAPASS
final ok