ELE19-01729
| Rough-In Permanent Service | 5/14/2019 | 5/14/2019 | 5/14/2019 2:23:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE19-01568
| Final | 5/14/2019 | 5/14/2019 | 5/14/2019 2:10:17 PM | P | PASS |
|
|
Chad Vanorden is contact ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Final ok
|
ELE19-01083
| Final | 5/14/2019 | 5/14/2019 | 5/14/2019 1:41:27 PM | P | PASS |
|
|
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden Disconnecting means on unit. Final ok
|
ELE18-00602
| Electrical Rough-In | 5/14/2019 | 5/14/2019 | 5/14/2019 1:22:07 PM | P | PASS |
|
|
ceiling // JOhn Phone #: ###-#### Level 2 grid rough in ok cover
|
ELE19-01766
| Electrical Rough-In | 5/13/2019 | 5/14/2019 | 5/14/2019 12:13:04 PM | A | PASS |
|
|
fiberglass pool bonding and u.g. lights Phone #: ###-#### Inspection requested via web by Kevin Koomler #8 run from equipment to edge of pool and underground rough in ok cover
|
ELE19-01173
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 11:43:32 AM | A | PASS |
|
|
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller Final ok
|
ELE19-00873
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 11:30:16 AM | A | PASS |
|
|
GARAGE CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE19-00997
| Permanent Service | 5/14/2019 | 5/14/2019 | 5/14/2019 10:52:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard p/s u/g n ok
|
ELE19-00934
| Final | 5/10/2019 | 5/14/2019 | 5/14/2019 10:37:43 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Steven Ragan 210.8(B)- All 15 and 20 amp receptacle outlets located with in 6' of a sink shall have GFCI protection. Refer, disposal.
|
ELE19-01729
| Rough-In Permanent Service | 5/13/2019 | 5/14/2019 | 5/14/2019 9:04:33 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 334.12- NM cable shall not be installed where subject to damage. NM run over wall header then back into stud bay above furnace platform. Secure AC wire so not to hang below truss bottom.
|