ELE16-00070
| ELE-Aging Inspection | 5/24/2019 | 5/24/2019 | 5/24/2019 3:22:31 PM | | FAIL |
|
|
Waiting on contractor to respond
|
ELE19-01903
| Permanent Service | 5/23/2019 | 5/24/2019 | 5/24/2019 3:12:36 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jeremy Cloud 110.24- Available fault current shall be posted prior to permenant service inspection. Had verbal with wireman
|
ELE19-01872
| Final | 5/23/2019 | 5/24/2019 | 5/24/2019 2:34:59 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Tricia Henderson No one home. Must include description of work performed. Will not search to locate item added.
|
ELE19-00374
| Rough-In Permanent Service | 5/24/2019 | 5/24/2019 | 5/24/2019 2:14:16 PM | P | PASS |
|
|
Tom Phone #: ###-#### Underground to service not connected to service. Rough in ok cover p/s u/g n ok
|
ELE18-04603
| Rough-In Permanent Service | 5/24/2019 | 5/24/2019 | 5/24/2019 2:13:01 PM | P | PASS |
|
|
Tom Phone #: ###-#### Underground to service not connected to service. Garage rough in ok cover p/s u/g n ok
|
ELE19-01927
| Electrical Rough-In | 5/24/2019 | 5/24/2019 | 5/24/2019 1:49:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Underslab rough in ok cover
|
ELE19-01483
| Final | 5/21/2019 | 5/24/2019 | 5/24/2019 1:13:38 PM | P | NR |
|
|
Please call ahead Phone #: ###-#### Inspection requested via web by Kyle Dillon Metermain relocated to ground level. Will recall when grounds and neutrals seperation complete in panel. No other alterations allowed in this panel.
|
ELE19-01483
| Rough-In Permanent Service | 5/21/2019 | 5/24/2019 | 5/24/2019 1:11:15 PM | A | PASS |
|
|
Please call ahead Phone #: ###-#### Inspection requested via web by Kyle Dillon p/s o/h rec ok
|
ELE19-00619
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 12:56:22 PM | P | PASS |
|
|
or all ###-#### Phone #: ###-#### Inspection requested via web by Robert Murray Final ok
|
ELE19-00962
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 12:42:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey Final ok
|
ELE19-01847
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 12:05:21 PM | P | PASS |
|
|
Final inspection in conjunction with Old Dominion Solar
Thank you and have a wonderful long weekend! Phone #: ###-#### Inspection requested via web by JENNY EMEL Final ok
|
ELE19-01782
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 11:59:02 AM | A | PASS |
|
|
Please Call before Inspection Phone #: ###-#### Inspection requested via web by Matt Oranday Final ok
|
ELE19-00482
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 11:23:53 AM | A | FAIL |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn 110.3- Devices shall be installed as per instructions. Up short hall 3-way not working. 210.12- Level 1 office or bedroom shall have AFCI protection. Clothes rod present. 210.8- GFCI device shall be located in a readily accessible location not behind or inder tub deck. * Ensure access operational for jetted tub motor. * Small garage door not working. No access to check receptacle
|
ELE19-00875
| Final | 5/24/2019 | 5/24/2019 | 5/24/2019 10:19:10 AM | A | FAIL |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn 314.25- Buried recessed can hall out guest bedroom. 410.16- Guest closet shall have completely enclosed lamps. Globe missing.
|
ELE19-01656
| Electrical Rough-In | 5/23/2019 | 5/24/2019 | 5/24/2019 9:42:38 AM | A | FAIL |
|
|
Soffit inspection Phone #: ###-#### Inspection requested via web by Ryan Wake 110.3- Soffit can fire hoods shall be installed as per manufacturers instructions. Only small openings are prmitted for entrance of conductors. Hoods are split from soffit to roof.
|
ELE19-01018
| Electrical Rough-In | 5/23/2019 | 5/24/2019 | 5/24/2019 9:08:30 AM | A | PASS |
|
|
walls Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Perimeter shell walls rough in ok cover
|
ELE19-00962
| Conference | 5/24/2019 | 5/24/2019 | 5/24/2019 8:19:52 AM | A | FAIL |
|
|
code 3484 Phone #: ###-#### Inspection requested via web by Neal Rumsey Needed final inspection. Corrections not complete, refer still reverse polarity. Recall
|
ELE19-01825
| Temporary Service | 5/23/2019 | 5/24/2019 | 5/24/2019 7:34:48 AM | A | CANC |
|
|
Jake is the contact Phone #: ###-#### >> Inspection requested via web by Deb Ipsen Inspection cancelled from web by: Deb Ipsen
|