MIS18-00163
| ESC-Conference | 5/3/2018 | 5/3/2018 | 5/7/2018 11:39:33 AM | P | DONE |
|
|
Complaint about dust from interior demolition materials received...
Dumpster has wall board in it, no work or dust at time of inspection. No dust blowing out of dumpster observed.
No exterior disturbance or excavation. Demolition is covered by BLD18-01222
|
ESC16-00945
| General Inspection | 5/3/2018 | 5/3/2018 | 5/7/2018 8:03:31 AM | | PASS |
|
|
|
ESC16-00741
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 2:25:30 PM | P | PASS |
|
|
Permits posted. No spills, discharges, or trackout occuring. No fugitive dust observed or reported. Receiving storm drains have inlet protection.
|
ESC17-00847
| Complaint Inspection | 5/2/2018 | 5/3/2018 | 5/3/2018 2:19:09 PM | A | PEND |
|
|
Dust occuring when using heavy equipment. No water truck observed operating at time of inspection but there is a water trailer onsite.
Notified project manager (Michael) to tell operators to drive slower than 5 mph. Use water trailer during high activity days, have water available to crust down haul routes.
New construction entrance was installed as requested during site prep.
|
ESC17-01132
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 2:05:17 PM | P | PASS |
|
|
Construction entrance installed. Concrete and masonry lined washout pit located next to job trailer. Covered storage for materials provided, fuel tank has secondary containment. Water truck is spraying down access around the building 2x daily to keep down dust. No dust issues observed at time of inspection.
Correction to work on for next inspection: - post CGP 2017 required SWPPP notifiication and new green COB ESC sign at entrance or on job sign.
|
ESC16-01253
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 2:02:58 PM | | CANC |
|
|
|
ESC17-01220
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 1:35:35 PM | P | PASS |
|
|
WIP on interior. Located next to CVS site, see ESC17-01011. No spills, dust, or other violations observed, permit posted on SLBS job trailer in front old Hastings.
|
ESC17-01011
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 1:33:14 PM | P | PASS |
|
|
WIP on new CVS. Storm drains on Cole and in parking lot have sediment protection. Ecopan concrete washout in use at site.
Discussed with onsite manager Mark to request water truck for dust control for forklift moving around site. He stated water truck will be in use this afternoon.
Trash contained, no trackout. Approved.
|
ESC12-00403
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 12:11:39 PM | | PASS |
|
|
|
ESC17-00956
| Aging Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 11:38:27 AM | | PASS |
|
|
WIP in backyard. Access via alley. No violations observed. Frame is up.
|
ESC16-01410
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 11:33:01 AM | P | PEND |
|
|
Staging area and access road to top of Camel's Back has revegetated well, no erosion or runoff issues observed.
Rock retaining walls have helped stabilized the chute, but areas in between have sparse vegetation growing through erosion control blanket. Some areas of blanket are improperly installed and not trench in at top of slope and perpinducular to slope.
Will check with PW Hillside and Parks n Rec to see if we want to have these installations fixed and a more native mix installed.
|
ESC17-00420
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 11:09:08 AM | | PASS |
|
|
home demo complete, site is cleaned and vegetated. ESC permit finaled.
|
ESC17-00420
| DOC - Permit Finaled | 5/3/2018 | 5/3/2018 | 5/3/2018 11:09:00 AM | P | PASS |
|
|
|
ESC17-00416
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 11:03:58 AM | | PART |
|
|
No trackout or discharges to Sand Dune. Trash relatively contained.
Correction request to Justin Jayo voicemail
- remove collected dirt behind wattle in the backyard to increase capacity. - fix rill/channel that has developed between the twon home - pick up any loose trash and put in container.
|
ESC17-00704
| General Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 10:37:56 AM | | PASS |
|
|
WIP on interior, perimeter wattles installed. Site using adjacent lot for parking, construction entrance rock installed. No violations observed.
|
ESC18-00581
| Site Preparation | 5/3/2018 | 5/3/2018 | 5/3/2018 10:30:20 AM | A | PASS |
|
|
Call prior to going Phone #: 2088598694 >> Inspection requested via mobile web by Brad
Will utilize existing access to building site behind home. Onsite broom staged next to exit for regular sweeping. Downstream storm drain already has an old sediment bag installed with capacity. RP will monitor. Permit sign posted.
Concrete washout provided on flat area at end of drive. Will install sediment control wattles around stockpiles and along the base of access drive where there is a potential for runoff to go over neighbors wall.
Approved for construction.
|
ESC16-01031
| Aging Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 8:25:14 AM | | CANC |
|
|
|
ESC16-01030
| Aging Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 8:25:02 AM | | CANC |
|
|
|
ESC16-01029
| Aging Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 8:24:39 AM | | CANC |
|
|
|