Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00141 General Inspection6/17/20206/17/20206/18/2020 11:50:28 AM PASS
WIP on framing and site work. Site is being keppt clean. No trackout onto Fed Way. Some mud on apron, rock entrance needs repair. New sidewalks installed, still have wattle on perimeter. No trash blown into field.
ESC20-00214 BMP Violation6/10/20206/17/20206/17/2020 2:15:15 PMAPASS
Washout made of silt fence removed. No new concrete work.
ESC16-00353 General Inspection6/17/20206/17/20206/17/2020 2:05:05 PM PASS
No issues from rain event.
ESC19-01192 General Inspection6/17/20206/17/20206/17/2020 12:35:43 PM PASS
Site has retained buffers, nothing leaving site.
Curbing completed, road bed ready for paving.
Lots of standing water in parking and staging area.
ESC19-01191 General Inspection6/17/20206/17/20206/17/2020 12:34:20 PM PASS
Site has retained buffers, nothing leaving site.
Curbing completed, road bed ready for paving.
Lots of standing water in parking and staging area.
ESC19-00221 Aging Inspection6/17/20206/17/20206/17/2020 12:25:25 PM PASS
WIP on block. No dumped washout. Most exterior work completed. No issues.
ESC19-00371 General Inspection6/17/20206/17/20206/17/2020 12:02:01 PMPFAIL
Did turbidity sample on site. Meter is calibrated, certified by manufacture, and less than 30 days old.
Trent Point Inlet :146 NTU
Vortex inlet : 51.4 NTU
Vortex Pond Surface: 67.5 NTU
Vortex Pond Outlet: 104 NTU
Dame Face East Pipe:95.9 NTU
Dam Face West Pipe: 82.7 NTU
Creek Below Dam: 134 NTU
Flow Under Dewatering Bag from Reservoir Dewatering: 489 NTU
Flume where dewatering water joins creek: 262 NTU
Site is out of compliance. Water turbidity was 146 NTU in, 262 NTU out. Increase of 116 NTU.
ESC19-00842 Aging Inspection6/17/20206/17/20206/17/2020 9:50:35 AM CANC
ESC19-00842 DOC - Permit Finaled6/17/20206/17/20206/17/2020 9:50:27 AMPPASS
ESC16-00935 General Inspection6/17/20206/17/20206/17/2020 9:40:15 AM PASS
Storm drain system working, no issues.
ESC18-00920 General Inspection6/17/20206/17/20206/17/2020 9:38:06 AMPPASS
No dirt flowing off site, some cones added to try to keep people off site.
ESC20-00499 Site Preparation6/16/20206/17/20206/17/2020 9:26:07 AMPPASS
Will preserve vegetation, entrance through allley. Storm drains are a few blocks from site and won't need protection. Let them know to keep up with sweeping while excavating.