Inspections for the day of: Tuesday, June 26, 2018.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-00555 Final6/26/20186/26/20186/26/2018 3:46:54 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-00549 Final6/26/20186/26/20186/26/2018 3:46:44 PMPPASS
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-02101 Final6/25/20186/26/20186/26/2018 3:33:45 PMPPASS
Please call Ted, Thank You! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
MEC18-02574 Final6/25/20186/26/20186/26/2018 3:33:26 PMPPASS
Please call Ted, Thank You! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
MEC18-02064 Pressure Test6/25/20186/26/20186/26/2018 3:02:26 PMPCANC
Please call ahead and speak with Greg Mendiola ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola
canc per conversation with greg
MEC18-02941 Final6/26/20186/26/20186/26/2018 2:08:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-02337 Pressure Test6/26/20186/26/20186/26/2018 1:58:04 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
need to use approved stricker plates, gas flex cannot be attatched to wall studs per installation instructions,fittings not installed per manufacturers installation instruction
MEC18-02337 Rough-in6/26/20186/26/20186/26/2018 1:55:24 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
bedrooms in basement need return path,
floor boots in basement need to be sealed to the floor,
MEC18-02338 Rough-in6/26/20186/26/20186/26/2018 1:53:44 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
will pass when pressure test is passed
MEC18-02338 Pressure Test6/26/20186/26/20186/26/2018 1:53:14 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
flash shield corrections still need to be made
MEC18-02980 Final6/26/20186/26/20186/26/2018 1:29:45 PMPPASS
Please inspect before 3 PM. Contractor only there until 3. Loren ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-00876 Final6/21/20186/26/20186/26/2018 1:21:04 PMPPASS
Phone #: ###-#### Inspection requested via web by David Petsche
MEC18-01163 Final6/26/20186/26/20186/26/2018 1:04:08 PMPFAIL
CALL FOR EX Phone #: ###-#### Inspection requested via web by Oleg Chervak
need blast test and balance report
MEC18-01164 Final6/26/20186/26/20186/26/2018 1:03:27 PMPFAIL
CALL FOR EX Phone #: ###-#### Inspection requested via web by Oleg Chervak
need blast test and balance report
MEC18-02763 Rough-in6/25/20186/26/20186/26/2018 11:28:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
MEC18-02763 Pressure Test6/25/20186/26/20186/26/2018 11:28:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
20lb gas
MEC18-02764 Rough-in6/25/20186/26/20186/26/2018 11:03:57 AMANR
Phone #: ###-#### Inspection requested via web by Debbie Marino
MEC18-02764 Pressure Test6/25/20186/26/20186/26/2018 11:03:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
20 lb gas
MEC18-02326 Rough-in6/25/20186/26/20186/26/2018 10:49:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC18-02821 Final6/19/20186/26/20186/26/2018 10:46:39 AMAPASS
Please call Brian 30 minutes in advance for access at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs
MEC18-01013 Rough-in6/25/20186/26/20186/26/2018 9:54:04 AMAFAIL
Partial rough in 1st floor area B. Please call Todd 20 min prior. Thank you Phone #: ###-#### Inspection requested via web by Kim Adams
need city stamped set on site, for inspection
MEC18-02665 Rough-in6/25/20186/26/20186/26/2018 9:04:11 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino
Bvent needs insulation shield, all exhaust fans need to be tied in, 6" fresh air back to return plenum not return can, all floor boots need to be sealed to the floor
MEC18-01529 Final6/25/20186/26/20186/26/2018 9:02:47 AMPCANC
Phone #: ###-#### >> Inspection requested via web by David Petsche Inspection cancelled from web by: David Petsche
MEC18-02665 Pressure Test6/25/20186/26/20186/26/2018 9:01:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
20 lb gas
MEC18-01213 Final6/25/20186/26/20186/26/2018 8:46:44 AMAPASS
Key to get in the house is on post by the fro t door Phone #: ###-#### Inspection requested via web by Dennis Hayden
MEC18-01446 Final6/25/20186/26/20186/26/2018 8:46:28 AMACANC
Duct blast witness at 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
canc. per conv. with logan
MEC18-01446 Final6/25/20186/26/20186/25/2018 10:40:04 AMACANC
Duct witness at 11am Please Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves