Inspections for the day of: Thursday, June 28, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-01082 General Inspection6/28/20186/28/20186/28/2018 3:22:24 PM PASS
WIP. Very small amount of disturbance, all contained to site. Material and stones being store in parking lot across Hays.
No ESC issues.
ESC16-00935 General Inspection6/28/20186/28/20186/28/2018 3:06:54 PM PASS
Hillsides are stable. New trenches for power, stockpile on site, very close to being in road. Unable to check drainage below home, trench blocked access on one side, scaffolding on other. Trash is contained at both sites, right of way not being used for storage. No ESC issues at either site.
ESC16-00936 General Inspection6/28/20186/28/20186/28/2018 3:06:37 PM PASS
Hillsides are stable. New trenches for power, stockpile on site, very close to being in road. Unable to check drainage below home, trench blocked access on one side, scaffolding on other. Trash is contained at both sites, right of way not being used for storage. No ESC issues at either site.
ESC18-00885 Complaint Inspection6/28/20186/28/20186/28/2018 1:13:38 PMPPART
Construction entrance on Forsythia needs to be repaired.
Site is free from dust during gusty winds. Hauling away fill material, some dust while dumping bucket into trucks.
Road is torn up from sewer, hasn't been patched, some dust while trucks drive away down Forsythia, lots of dirt on road.
Looks like trucks are pulling in and turning around on lot just before 34th, no rocks or other stabalization in area, rock pad should be constructed if area going to continue to be used as a turn around.
Large stockpile on site has been sprayed with tackifier.
Inlets on Lassen have been protected, very small construction exit built.
Winds at time of inspection were blowing towards Hill & N 33rd.
ESC17-00862 Aging Inspection6/28/20186/28/20186/28/2018 12:11:27 PM PASS
All ground disturbances complete. Will final when building permit closed.
ESC17-01179 Aging Inspection6/28/20186/28/20186/28/2018 12:00:06 PM PASS
Small pile of dirt out in yard. Contained in yard, no ESC issues.
ESC18-00558 General Inspection6/25/20186/28/20186/28/2018 11:51:20 AMAPASS
Two neighboring lots. Still large piles of backfill. Perimeter controls are old and will need repair. Some dirt goes right onto slope drainage channel. Pump truck onsite, was using washout.
ESC18-00392 General Inspection6/25/20186/28/20186/28/2018 11:51:07 AMAPASS
Two neighboring lots. Still large piles of backfill. Perimeter controls are old and will need repair. Some dirt goes right onto slope drainage channel. Pump truck onsite, was using washout.
ESC13-01279 General Inspection6/28/20186/28/20186/28/2018 9:30:31 AM PASS
Some of the perimeter silt fence has collapsed, acting more as fence than containment. Idaho power is currently on site. Site is mostly clean, some bottles and trash stuck on fence. No dust or trackout.
ESC16-01561 General Inspection6/20/20186/28/20186/28/2018 9:22:31 AMPPASS
No blowing trash. Few lots have lots of building waste on site. Concrete washouts will soon need to be emptied.
ESC15-00094 General Inspection6/28/20186/28/20186/28/2018 9:20:53 AM PASS
Few homes under construction. No ESC issues in neighborhood. Each home is responsible for their own BMPs.
ESC17-00791 General Inspection6/18/20186/28/20186/28/2018 9:08:04 AMPPASS
Area has had slopes hydroseeded and flats tackified. Will soon turn property over to builders.