MEC19-02831
| Rough-in | 7/12/2019 | 7/12/2019 | 7/12/2019 3:57:35 PM | P | PASS |
|
|
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor
|
MEC19-02831
| Pressure Test | 7/12/2019 | 7/12/2019 | 7/12/2019 3:55:33 PM | P | PASS |
|
|
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20 lb gas pass tagged meter location- 5lb flue pass
|
MEC19-02925
| Final | 7/9/2019 | 7/12/2019 | 7/12/2019 3:37:42 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC19-02832
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 2:44:42 PM | P | PASS |
|
|
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC19-02787
| Pressure Test | 7/11/2019 | 7/12/2019 | 7/12/2019 1:37:21 PM | P | FAIL |
|
|
This is ready for 3 inspections altogether including underground, pressure test and manu home connect final. Contact Buck at ###-#### with questions. Phone #: ###-#### Inspection requested via web by jamie berg- gas piping need approved manufactured flex gas line installed at side of mobile home can not be hard tie in- dont see a/c- will need to get inside unit to check coil and drains- lineset needs ran- retest system when flex connector is installed on gas line
|
MEC19-02973
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 1:19:57 PM | P | PASS |
|
|
There is a lock box at the front door, code is 208 Phone #: ###-#### Inspection requested via web by Arcadio Martinez- R/I ok- will need to add 10" damper to supply line where sidewall register is by final- need approved prints onsite at final- contractor will be onsite for roof access at final
|
MEC19-02727
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 12:01:40 PM | A | FAIL |
|
|
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek 1- need to seal all supply and retun air registers- 2- supply duct in garage joists is below joists and insulated to r8 3- fresh air can not come from register can needs to be from plenum 4- b vent in garage at ceiling needs 1" clearance to wood and attic needs draft stop installed and firecaulked 5- house needs 2 gable end vents in attic to draw combustion air from attic for laundry room 6- framing needs completed around supply/return and b vent chase and draft stop installed around supply and return ducting 7- need fresh air to upstairs downstairs unit didnt see any 8- need nail plate on dryer duct at ceiling 9- south furnace model # does not match man j need to submit whats installed 10- R/A panning in garage needsremoved and ran in pipe and insulated to r6 unconditioned space- left notice front window
|
MEC19-02958
| Pressure Test | 7/11/2019 | 7/12/2019 | 7/12/2019 11:51:44 AM | A | PASS |
|
|
60# on 3/4 line. 20# on manifold. Thanks. Phone #: ###-#### Inspection requested via web by Don Headrick - 60lb gas pas- 20lb gas pass- will look at piping on other mechanical inspection
|
MEC19-01765
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 11:35:43 AM | A | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- 1- need duct blast test completed and stickered 2- resubmit man j for approval of condenser brand used and have new approved man j onsite 3- b vent for 2 water heaters is undersized for 80000 btu need to reconfigure and install new 4 primay drain off coil to drain has backgrade
|
MEC19-01378
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 11:26:36 AM | A | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need to resubmit man j condenser is different brand name and have approved man j onsite 2- need protection post installed in garage in front of supply duct where zone damper is
|
MEC19-02994
| Final | 7/12/2019 | 7/12/2019 | 7/12/2019 11:07:57 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by claude croy- need to add bath fan to permit and pay fee to final out
|
MEC19-02994
| Rough-in | 7/12/2019 | 7/12/2019 | 7/12/2019 11:07:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by claude croy- R/I ok- need to add bath fan to permit and pay fee
|
MEC19-02727
| Pressure Test | 7/11/2019 | 7/12/2019 | 7/12/2019 10:57:30 AM | A | PASS |
|
|
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- 60lb gas pass tagged meter- 20lb gas pass- 5lb flue pass
|
MEC19-02181
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 9:58:00 AM | A | PASS |
|
|
bathrooms and offices, Robert is your contact. Phone #: ###-#### Inspection requested via web by stan lillquist- 2 fire/smoke damper framong and clearances ok, ok for angles- seal on ducts in classrooms, offices and bathrooms ok- ok to cover- still need to look at linesets for a/cs and minisplits- ok for ceiling grid
|
MEC19-02971
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 9:20:09 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Robert J Mahler- per conversation with GC onsite- one fan needs move in master bath to accomendate grill- call in when all fans are ready and need ladder onsite to access attic
|
MEC19-02420
| Final | 7/8/2019 | 7/12/2019 | 7/12/2019 9:08:32 AM | A | FAIL |
|
|
Please call Dan on way to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- primary and secondary drains and arma flex need to be 6" clearance to single wall flue
|
MEC19-02938
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 8:46:00 AM | A | PASS |
|
|
Mechanical Gas fireplace rough in inspection Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC19-01632
| Final | 7/12/2019 | 7/12/2019 | 7/12/2019 8:36:23 AM | A | PASS |
|
|
Call before you are on your way if possible for access 208 631 6575 Inspection requested via web by jeff jedlick
|
MEC19-02831
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 8:11:43 AM | A | FAIL |
|
|
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor- need approved manual j onsite couldnt find one- few items went over with installer havent been fixed see yesterday notes
|
MEC19-02831
| Pressure Test | 7/11/2019 | 7/12/2019 | 7/12/2019 8:10:39 AM | A | FAIL |
|
|
With Rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- need flue under test- 20lb gas pass
|
MEC19-02841
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 8:10:09 AM | A | PASS |
|
|
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC19-02974
| Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 8:09:55 AM | A | PASS |
|
|
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC18-03877
| Mec-Aging Inspection | 7/12/2019 | 7/12/2019 | 7/12/2019 7:56:49 AM | | CANC |
|
|
|
MEC18-03877
| DOC - Permit Expired | 7/12/2019 | 7/12/2019 | 7/12/2019 7:56:38 AM | P | PASS |
|
|
work done under another permit
|
MEC19-02832
| Final | 7/8/2019 | 7/12/2019 | 7/11/2019 7:34:20 AM | P | CANC |
|
|
installer Travis ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|