Inspections for the day of: Tuesday, July 25, 2017.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01549 Electrical Rough-In7/24/20177/25/20177/25/2017 2:05:21 PMPPASS
Underground for fiber optic lines. Shane is the contact his cell is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates
Capitol north 1/2 for street lights, Idaho st fiber underground rough in ok cover noted in office
ELE17-02381 Conference7/24/20177/25/20177/25/2017 11:02:35 AMADONE
Please call ahead for access - Scott Phone #: ###-####
Discussed all codes covering residential wiring. Service change required due to unfused conductors entering structure. Discussed mast, disconnect, grounding electrode system, plumbing and ground rod. Panel location is partially covered by water heater, new location required, mey use as junction point. Talked receptacle spacing for habitable rooms and kitchen counter top areas and bathroom dedicated 20 amp and location. All junction points shall be accessible, saw old and new splices. Discussed tamper resistant type and weather resistant type receptacles. GFCI protection for all bath, outdoor, kitchen counter top receptacles, AFCI protection for new wiring in bedrooms, only new in master bed planned. Scope of work to include new master bed and bath, kitchen area, laundry area and service.
Informed homeowners are required to do work with help from immediate family only.
ELE17-01959 Electrical Rough-In7/24/20177/25/20177/25/2017 9:35:06 AMAPASS
Equipotential deck plan Phone #: ###-#### Inspection requested via web by Kevin Koomler
EQ plane and bond to gutter down spout rough in ok cover
ELE17-02097 Rough-In Permanent Service7/24/20177/25/20177/25/2017 9:06:13 AMAPASS
This is a re-inspection. Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Rough in ok cover p/s u/g n ok
ELE17-02096 Rough-In Permanent Service7/24/20177/25/20177/25/2017 9:05:37 AMAPASS
This is a re-inspection. Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Rough in ok cover p/s u/g n ok