ELE19-03155
| Rough-In Permanent Service | 8/22/2019 | 8/22/2019 | 8/22/2019 2:43:00 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt... 1) NMB shall have minimum of 1/4" of sheathing were entering a box...multiple locations in violation...ceiling and walls
|
ELE07-02082
| ELE-Aging Inspection | 8/22/2019 | 8/22/2019 | 8/22/2019 2:36:02 PM | | PASS |
|
|
still under construction...permit reopened as per Bob Archibald 8/21/19
|
ELE19-00136
| Final | 8/22/2019 | 8/22/2019 | 8/22/2019 2:34:55 PM | P | PASS |
|
|
All new electrical gear is installed, equipment is connected and in operation. Call with any questions. Kurt ###-#### Phone #: ###-#### Inspection requested via web by Kurt Carlson...labelling of breakers, AFI label, and new feeds into/out existing and new panel complete
|
ELE19-02494
| Electrical Rough-In | 8/22/2019 | 8/22/2019 | 8/22/2019 1:41:26 PM | P | PASS |
|
|
EQ bonding plane wiring ; connections Phone #: ###-#### Inspection requested via web by Lars Johnson...ok to cover
|
ELE19-02905
| Electrical Rough-In | 8/22/2019 | 8/22/2019 | 8/22/2019 1:05:06 PM | P | NR |
|
|
Nick Harris is contact at ###-####. Underground Inspection. Phone #: ###-#### Inspection requested via web by Debby Pierce.. spoke to contact...inspection needed for following Monday PM...rescheduled for 8/26/19
|
ELE19-02751
| Conference | 8/22/2019 | 8/22/2019 | 8/22/2019 12:27:18 PM | P | DONE |
|
|
disconnect, light and outlet in attic...was informed by mechanical inspector that HVAC unit was installed in attic and required electrical needed for servicing of equipment was not installed...verify at final that done
|
ELE19-02507
| Final | 8/21/2019 | 8/22/2019 | 8/22/2019 11:33:32 AM | A | PASS |
|
|
Call Matt Butler prior to going to site 503 309 1453 Inspection requested via web by Matt Phillips...ok to final...work done thru wall/surface
|
ELE19-02698
| Final | 8/22/2019 | 8/22/2019 | 8/22/2019 11:05:23 AM | A | PASS |
|
|
Equipment is connected and energized, panel schedule has been redone, breaker lock offs installed at panel. Call with any questions. Kurt ###-#### Phone #: ###-#### Inspection requested via web by Kurt Carlson..ok to final
|
ELE19-02902
| Electrical Rough-In | 8/21/2019 | 8/22/2019 | 8/22/2019 10:44:00 AM | A | FAIL |
|
|
Whole house and service Phone #: ###-#### Inspection requested via web by David McClellan...
**as per permit ELE19-01739..house accross street...UF wire installedwith no inspection...needs addressed**
1) all wires shall have a connector or attachment where enters box...bell box side of house...lot #108 and #113 accross street 2) 12/2 NMB and 14/2 NMB in same box and feeding a completed circuit...unable to verify circuit size and location in panel 3) nail plates required...mst bed switches and back door in dining...top plate 4) stack-it used to support/strap 8/3 NMB...exceeds manufacturers rating...12 and 14 NMB only 5) all metal boxes shall be grounded...LV panel
|
ELE19-03104
| Electrical Rough-In | 8/21/2019 | 8/22/2019 | 8/22/2019 9:26:30 AM | A | PASS |
|
|
fireplace rough-in inspection Phone #: ###-#### Inspection requested via web by Kevin Perez....rough complete...ok to cover
|
ELE19-02732
| Final | 8/21/2019 | 8/22/2019 | 8/21/2019 10:26:45 AM | A | PASS |
|
|
Call me Barry Spencer with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes... labelling, disconnect, and OCPD ok
|