ELE17-02077
| Electrical Rough-In | 8/7/2017 | 8/7/2017 | 8/7/2017 2:54:06 PM | P | PASS |
|
|
Inspection for floor heat in master bath. Phone #: ###-#### Inspection requested via web by Terry Scott Area noted rough in ok cover
|
ELE17-00116
| Electrical Rough-In | 8/7/2017 | 8/7/2017 | 8/7/2017 2:15:36 PM | P | PASS |
|
|
Ceiling Inspection level 1 Contact Jon Novak Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Area noted grid rough in ok cover
|
ELE17-01656
| Final | 8/7/2017 | 8/7/2017 | 8/7/2017 1:45:31 PM | P | PASS |
|
|
Shane is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
|
ELE17-01925
| Final | 8/4/2017 | 8/7/2017 | 8/7/2017 1:15:16 PM | P | PASS |
|
|
Call homeowner 1 hour in advance. He is typically only available around 12-1pm. Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Final ok
|
ELE17-02059
| Conference | 8/7/2017 | 8/7/2017 | 8/7/2017 1:08:18 PM | P | DONE |
|
|
Discussed code requirements for a metal wireway options to install approx. 120 current carrying conductors from panel board to ceiling space with out derating. As per 310.15(B)(3)- Shall not exceed 20% cross sectional area or 30 current carrying conductors in wireway, if exceed either derating shall apply. Dividing a large wireway into multiple is concidered same as installing seperate wireways. Also discussed if general contractor could one side wall with drywall. No one siding is permitted on nonbearing wall unless needed for equipment or firewalls.
|
ELE17-01549
| Electrical Rough-In | 8/4/2017 | 8/7/2017 | 8/7/2017 10:38:19 AM | A | PASS |
|
|
SHANE IS THE CONTACT HIS CELL NO IS ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Raceways for low volt tape lighting in sea walls rough in ok cover.
|
ELE17-02436
| Final | 8/6/2017 | 8/7/2017 | 8/7/2017 10:15:32 AM | A | PASS |
|
|
Please call 30 minutes ahead of time. I will be walking with the owner in the morning so please give me a heads up so I can meet you and provide access Phone #: ###-#### Inspection requested via web by Casey Fouts Final ok
|
ELE17-02492
| Final | 8/7/2017 | 8/7/2017 | 8/7/2017 10:01:28 AM | A | PASS |
|
|
Contact is Derek Ball Phone #: ###-#### Inspection requested via web by Scott Campbell Small stand alone system for bus stop. Listing confirmed. Final ok
|
ELE17-02091
| Final | 8/6/2017 | 8/7/2017 | 8/7/2017 9:39:39 AM | A | PASS |
|
|
Mechmasters will be on site after 9am. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle Final ok
|
ELE17-02091
| Electrical Rough-In | 8/7/2017 | 8/7/2017 | 8/7/2017 9:39:12 AM | P | PASS |
|
|
Mechmasters will be on site after 9am. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle New disconnects for each AC unit rough in ok cover
|
ELE17-02541
| Rough-In Permanent Service | 8/6/2017 | 8/7/2017 | 8/7/2017 9:28:00 AM | A | CANC |
|
|
Inspect service only Phone #: ###-#### Inspection requested via web by Ryan Schaffer Needed permanent service only
|
ELE17-02541
| Permanent Service | 8/7/2017 | 8/7/2017 | 8/7/2017 9:27:52 AM | P | PASS |
|
|
Inspect service only Phone #: ###-#### Inspection requested via web by Ryan Schaffer p/s o/h rec ok
|
ELE17-02354
| Rough-In Permanent Service | 8/4/2017 | 8/7/2017 | 8/7/2017 9:16:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dean Gernaat Fee due $135 for dwelling under 2500sq. ft $55 charged for service. Difference of $80. Call contractor informed. Rough in ok cover p/s u/g n ok
|