Inspections for the day of: Monday, August 7, 2017.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02077 Electrical Rough-In8/7/20178/7/20178/7/2017 2:54:06 PMPPASS
Inspection for floor heat in master bath. Phone #: ###-#### Inspection requested via web by Terry Scott
Area noted rough in ok cover
ELE17-00116 Electrical Rough-In8/7/20178/7/20178/7/2017 2:15:36 PMPPASS
Ceiling Inspection level 1
Contact Jon Novak
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Area noted grid rough in ok cover
ELE17-01656 Final8/7/20178/7/20178/7/2017 1:45:31 PMPPASS
Shane is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
ELE17-01925 Final8/4/20178/7/20178/7/2017 1:15:16 PMPPASS
Call homeowner 1 hour in advance. He is typically only available around 12-1pm.
Phone #: ###-#### Inspection requested via web by Christian Kilpatrick
Final ok
ELE17-02059 Conference8/7/20178/7/20178/7/2017 1:08:18 PMPDONE
Discussed code requirements for a metal wireway options to install approx. 120 current carrying conductors from panel board to ceiling space with out derating.
As per 310.15(B)(3)- Shall not exceed 20% cross sectional area or 30 current carrying conductors in wireway, if exceed either derating shall apply. Dividing a large wireway into multiple is concidered same as installing seperate wireways.
Also discussed if general contractor could one side wall with drywall. No one siding is permitted on nonbearing wall unless needed for equipment or firewalls.
ELE17-01549 Electrical Rough-In8/4/20178/7/20178/7/2017 10:38:19 AMAPASS
SHANE IS THE CONTACT HIS CELL NO IS ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates
Raceways for low volt tape lighting in sea walls rough in ok cover.
ELE17-02436 Final8/6/20178/7/20178/7/2017 10:15:32 AMAPASS
Please call 30 minutes ahead of time. I will be walking with the owner in the morning so please give me a heads up so I can meet you and provide access Phone #: ###-#### Inspection requested via web by Casey Fouts Final ok
ELE17-02492 Final8/7/20178/7/20178/7/2017 10:01:28 AMAPASS
Contact is Derek Ball Phone #: ###-#### Inspection requested via web by Scott Campbell
Small stand alone system for bus stop.
Listing confirmed. Final ok
ELE17-02091 Final8/6/20178/7/20178/7/2017 9:39:39 AMAPASS
Mechmasters will be on site after 9am. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle
Final ok
ELE17-02091 Electrical Rough-In8/7/20178/7/20178/7/2017 9:39:12 AMPPASS
Mechmasters will be on site after 9am. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle
New disconnects for each AC unit rough in ok cover
ELE17-02541 Rough-In Permanent Service8/6/20178/7/20178/7/2017 9:28:00 AMACANC
Inspect service only Phone #: ###-#### Inspection requested via web by Ryan Schaffer
Needed permanent service only
ELE17-02541 Permanent Service8/7/20178/7/20178/7/2017 9:27:52 AMPPASS
Inspect service only Phone #: ###-#### Inspection requested via web by Ryan Schaffer
p/s o/h rec ok
ELE17-02354 Rough-In Permanent Service8/4/20178/7/20178/7/2017 9:16:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Dean Gernaat
Fee due $135 for dwelling under 2500sq. ft $55 charged for service. Difference of $80. Call contractor informed.
Rough in ok cover p/s u/g n ok