BLD19-01821
| BLD-Final | 9/11/2019 | 9/12/2019 | 9/12/2019 5:14:36 PM | P | FAIL |
|
|
Need to install railing at double door... Temp glazing needed at bathroom...
|
BLD19-01095
| BLD-Framing/Rough-in | 9/11/2019 | 9/12/2019 | 9/12/2019 5:12:29 PM | P | FAIL |
|
|
Per plans- 6x6 DF #1 posts to bear down to foundation, supporting glue lam at garage... Per shear inspections walk thru, #3 shear walls to be blocked... Per plans- Stairway header to be (2)1.75x 18" LvL Provide Engineering for as built... Per plans- 2x Ledger to be attached with (2) 1/4x 4 1/2" SDS screws...
|
BLD19-02661
| BLD-Foundation | 9/12/2019 | 9/12/2019 | 9/12/2019 5:07:21 PM | P | PASS |
|
|
Work in progress...
|
BLD19-01852
| BLD-Framing/Rough-in | 9/11/2019 | 9/12/2019 | 9/12/2019 5:07:05 PM | P | FAIL |
|
|
Corrections not complete... Provide Engineering approval for cut top trusses, see red paint, first floor living room...
|
BLD19-01799
| BLD-Foundation | 9/12/2019 | 9/12/2019 | 9/12/2019 5:05:29 PM | P | PASS |
|
|
Work in progress...
|
BLD19-01798
| BLD-Foundation | 9/12/2019 | 9/12/2019 | 9/12/2019 5:05:18 PM | P | PASS |
|
|
Work in progress...
|
BLD19-01797
| BLD-Foundation | 9/12/2019 | 9/12/2019 | 9/12/2019 5:05:07 PM | P | PASS |
|
|
Work in progress...
|
BLD19-01776
| BLD-Foundation | 9/12/2019 | 9/12/2019 | 9/12/2019 5:04:56 PM | P | PASS |
|
|
Work in progress...
|
BLD18-01702
| BLD-Final | 9/12/2019 | 9/12/2019 | 9/12/2019 5:04:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laz Ponce
|
BLD18-01702
| DOC - Permit Finaled | 9/12/2019 | 9/12/2019 | 9/12/2019 5:04:32 PM | P | PASS |
|
|
|
BLD18-01702
| BLD-Blower Door Test Results | 9/12/2019 | 9/12/2019 | 9/12/2019 5:04:00 PM | P | DONE |
|
|
ACH50- 4.26
|
BLD18-03790
| BLD-Final | 9/11/2019 | 9/12/2019 | 9/12/2019 5:02:58 PM | P | FAIL |
|
|
Smoke/ Carbon detectors all need to be interconnected and working... Landing at Deck and Garage man door- floor not more than 7 3/4" below threshold...
|
BLD19-03073
| BLD-Final | 9/11/2019 | 9/12/2019 | 9/12/2019 12:08:21 PM | P | NR |
|
|
Alicia Phone #: ###-####
|
BLD19-00883
| BLD-Energy code compliance | 9/11/2019 | 9/12/2019 | 9/12/2019 11:41:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Clint Wall
|
BLD19-02213
| BLD-Wall Bracing | 9/11/2019 | 9/12/2019 | 9/12/2019 11:28:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gus Brandon
|
BLD19-03389
| BLD-Footing | 9/11/2019 | 9/12/2019 | 9/12/2019 11:27:51 AM | A | PASS |
|
|
John Phone #: ###-####
|
BLD19-02707
| BLD-Conference | 9/11/2019 | 9/12/2019 | 9/12/2019 11:23:41 AM | A | PASS |
|
|
Footing...
|
BLD19-01586
| BLD-Energy code compliance | 9/11/2019 | 9/12/2019 | 9/12/2019 11:23:13 AM | A | PASS |
|
|
Bob Phone #: ###-####
|
BLD19-01586
| BLD-Framing/Rough-in | 9/11/2019 | 9/12/2019 | 9/12/2019 11:23:03 AM | A | PASS |
|
|
Bob Phone #: ###-####
|
BLD18-01704
| BLD-Final | 9/12/2019 | 9/12/2019 | 9/12/2019 11:22:50 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laz Ponce
|
BLD18-01704
| DOC - Permit Finaled | 9/12/2019 | 9/12/2019 | 9/12/2019 11:22:38 AM | P | PASS |
|
|
|
BLD18-01704
| BLD-Blower Door Test Results | 9/12/2019 | 9/12/2019 | 9/12/2019 11:22:21 AM | P | DONE |
|
|
ACH50- 4.1
|
BLD19-02402
| BLD-Final | 9/12/2019 | 9/12/2019 | 9/12/2019 11:04:42 AM | P | PASS |
|
|
Eric Phone #: ###-####
|
BLD19-02402
| DOC - Permit Finaled | 9/12/2019 | 9/12/2019 | 9/12/2019 11:04:26 AM | P | PASS |
|
|
|
MIS15-00234
| MIS-Aging Inspection | 9/12/2019 | 9/12/2019 | 9/12/2019 10:46:38 AM | | DEFR |
|
|
No word from Hot Topic
|
BLD18-02101
| BLD-Aging Inspection | 9/12/2019 | 9/12/2019 | 9/12/2019 10:41:24 AM | | DEFR |
|
|
|
BLD18-02101
| Extend Permit 90/180 days | 9/12/2019 | 9/12/2019 | 9/12/2019 10:41:06 AM | P | DONE |
|
|
|
BLD18-00632
| BLD-Conference | 9/11/2019 | 9/12/2019 | 9/12/2019 8:32:24 AM | A | CANC |
|
|
Jim Phone #: ###-####
|
BLD19-03073
| BLD-Final | 9/11/2019 | 9/12/2019 | 9/12/2019 8:22:50 AM | A | DEFR |
|
|
Alisia Phone #: ###-####
|
BLD19-02669
| BLD-Footing | 9/11/2019 | 9/12/2019 | 9/11/2019 3:16:05 PM | A | CANC |
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru Inspection cancelled via mobile web on Wednesday, September 11, 2019.
|