Inspections for the day of: Tuesday, September 24, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03342 ELE-Aging Inspection9/24/20199/24/20199/24/2019 4:16:48 PM PASS
See final
ELE17-03342 Final9/24/20199/24/20199/24/2019 4:16:12 PMPPASS
Job completed under EE17-03643. Final ok
ELE19-02718 Final9/24/20199/24/20199/24/2019 3:16:38 PMPPART
Inspection status from yesterday: Non-approved wiring methods in storage room, open junction box, no all receptacles in service-bay have GFCI protection, Waiting for Paint booth ETL listing tag authenticity.

All of the above code violations have been addressed. Just waiting for ETL authenticity
Phone #: ###-#### Inspection requested via web by Keith Chetta
Listing of paint booth still needs condirmed. TCO for rest of building ok
No card posted
ELE19-02966 Electrical Rough-In9/19/20199/24/20199/24/2019 2:50:52 PMAFAIL
Phone #: ###-#### Inspection requested via web by Icon Electric
210.52- In habitable rooms walls 2' or wider shall have a receptacle outlet installed.
334.30- NM cable shall be secured with in 12" of a box. Disposal receptacle. * Did not include permanent service in inspection.
Gave verbal ok to foam seal at 2:50pm.
ELE19-03616 Electrical Rough-In9/24/20199/24/20199/24/2019 2:47:18 PMPPASS
Daniel Phone #: ###-####
Exterior wall cover removed on north,east and south sides of residence. Wiring added to rooms from exposed walls.
Exterior wall cover rough in ok cover
ELE19-03616 Conference9/24/20199/24/20199/24/2019 2:45:43 PMPPASS
Daniel Phone #: ###-####
Owner has pamphlet from previous work performed. Discussed box fill, required outdoor receptacles at front patio and replace illegal receptacle wiring for receptacle with in 25' of AC unit.
ELE19-03550 Final9/24/20199/24/20199/24/2019 1:44:45 PMPFAIL
cONTACT IS dAN bORA Phone #: ###-#### Inspection requested via web by Scott Campbell BCC 4-05-32- No code violation shall be retained.
BCC 4-05-17- Inspector shall have access to all electrical in area where work has been performed.
Fresh glue in area re worked.
Unable to locate print.
300.15- All raceways shall terminate in a box. Flex with exposed wiring hanging out near corner opposite of refrigerator.
314.23- Boxes shall be secured to bulding structure. Boxes hangin on raceways centered from refer wall to corner. Fix exposed wiring where flex is damaged.
ELE19-02888 Final9/23/20199/24/20199/24/2019 1:36:05 PMPFAIL
Call Scott for access. He will meet you at corner of capital and front street.
###-#### Phone #: ###-#### Inspection requested via web by mike brown
Called contact at 12:55pm, unable to leave message due to voise mail has not been set up yet. At 1:35 no return call will be out of area for the rest of the day. Please recall when some one is available for access.
ELE19-02687 Final9/23/20199/24/20199/24/2019 12:46:16 PMAPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk
Final ok
ELE19-03554 Temporary Service9/23/20199/24/20199/24/2019 11:17:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE19-03609 Temporary Service9/23/20199/24/20199/24/2019 10:43:56 AMAFAIL
Phone #: ###-#### Inspection requested via web by ron spen cer
406.4(C)- Receptacles shall be connected to a equipment grounding conductor. Grounding conductor connector broke off 120 volt receptacle.
408.41- Grounded conductors shall termnate in its own terminal.
ELE19-00838 Final9/23/20199/24/20199/24/2019 10:24:42 AMAFAIL
Phone #: ###-#### Inspection requested via web by ron spen cer
200.6- White conductor used as other than grounded conductor shall be identified other than white in AC disconnect.
210.8(A)- Unable to located GFCI device for christmas receptacle in soffit, exception to outdoor receptacle fed off garage circuit is for readily accessible receptacles only.
210.52(A)- Area above cabinets at each side of fireplace is wall space and shall have a receptacle outlet located with in 6' of fire place. Receptacles located inside cabinets do not count.
210.52(C)- Counter top located in pantry shall have receptacles installed so that at no point measured along wall line is more than 24" from a receptacle outlet.
210.70- Required luminaire located at garage man door not working.
314.23(B)(1)- Island receptacle boxes shall not be secured by screws thru side of boxes.
334.30- NM cable shall be secured with in 12" of island receptacle box.
352.30- PVC service riser shall be secured with in 3' of meter base. strap in place but not secured.
406.6- Outdoor receptacle in use cover on east side of garage not completely secured. Missing screw.
BCC 9-05-17- It shall be unlawful to block electrical inspectors access to electracal associated with dwelling. Move master bed dresser and bed a minimum of 3' from wall to provide access to receptacles.
ELE19-03130 Electrical Rough-In9/23/20199/24/20199/24/2019 9:13:04 AMAPASS
Call Luke with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Clayton Morgan
Hardlids rough in ok cover