ELE17-03342
| ELE-Aging Inspection | 9/24/2019 | 9/24/2019 | 9/24/2019 4:16:48 PM | | PASS |
|
|
See final
|
ELE17-03342
| Final | 9/24/2019 | 9/24/2019 | 9/24/2019 4:16:12 PM | P | PASS |
|
|
Job completed under EE17-03643. Final ok
|
ELE19-02718
| Final | 9/24/2019 | 9/24/2019 | 9/24/2019 3:16:38 PM | P | PART |
|
|
Inspection status from yesterday: Non-approved wiring methods in storage room, open junction box, no all receptacles in service-bay have GFCI protection, Waiting for Paint booth ETL listing tag authenticity.
All of the above code violations have been addressed. Just waiting for ETL authenticity Phone #: ###-#### Inspection requested via web by Keith Chetta Listing of paint booth still needs condirmed. TCO for rest of building ok No card posted
|
ELE19-02966
| Electrical Rough-In | 9/19/2019 | 9/24/2019 | 9/24/2019 2:50:52 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Icon Electric 210.52- In habitable rooms walls 2' or wider shall have a receptacle outlet installed. 334.30- NM cable shall be secured with in 12" of a box. Disposal receptacle. * Did not include permanent service in inspection. Gave verbal ok to foam seal at 2:50pm.
|
ELE19-03616
| Electrical Rough-In | 9/24/2019 | 9/24/2019 | 9/24/2019 2:47:18 PM | P | PASS |
|
|
Daniel Phone #: ###-#### Exterior wall cover removed on north,east and south sides of residence. Wiring added to rooms from exposed walls. Exterior wall cover rough in ok cover
|
ELE19-03616
| Conference | 9/24/2019 | 9/24/2019 | 9/24/2019 2:45:43 PM | P | PASS |
|
|
Daniel Phone #: ###-#### Owner has pamphlet from previous work performed. Discussed box fill, required outdoor receptacles at front patio and replace illegal receptacle wiring for receptacle with in 25' of AC unit.
|
ELE19-03550
| Final | 9/24/2019 | 9/24/2019 | 9/24/2019 1:44:45 PM | P | FAIL |
|
|
cONTACT IS dAN bORA Phone #: ###-#### Inspection requested via web by Scott Campbell BCC 4-05-32- No code violation shall be retained. BCC 4-05-17- Inspector shall have access to all electrical in area where work has been performed. Fresh glue in area re worked. Unable to locate print. 300.15- All raceways shall terminate in a box. Flex with exposed wiring hanging out near corner opposite of refrigerator. 314.23- Boxes shall be secured to bulding structure. Boxes hangin on raceways centered from refer wall to corner. Fix exposed wiring where flex is damaged.
|
ELE19-02888
| Final | 9/23/2019 | 9/24/2019 | 9/24/2019 1:36:05 PM | P | FAIL |
|
|
Call Scott for access. He will meet you at corner of capital and front street. ###-#### Phone #: ###-#### Inspection requested via web by mike brown Called contact at 12:55pm, unable to leave message due to voise mail has not been set up yet. At 1:35 no return call will be out of area for the rest of the day. Please recall when some one is available for access.
|
ELE19-02687
| Final | 9/23/2019 | 9/24/2019 | 9/24/2019 12:46:16 PM | A | PASS |
|
|
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE19-03554
| Temporary Service | 9/23/2019 | 9/24/2019 | 9/24/2019 11:17:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE19-03609
| Temporary Service | 9/23/2019 | 9/24/2019 | 9/24/2019 10:43:56 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer 406.4(C)- Receptacles shall be connected to a equipment grounding conductor. Grounding conductor connector broke off 120 volt receptacle. 408.41- Grounded conductors shall termnate in its own terminal.
|
ELE19-00838
| Final | 9/23/2019 | 9/24/2019 | 9/24/2019 10:24:42 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer 200.6- White conductor used as other than grounded conductor shall be identified other than white in AC disconnect. 210.8(A)- Unable to located GFCI device for christmas receptacle in soffit, exception to outdoor receptacle fed off garage circuit is for readily accessible receptacles only. 210.52(A)- Area above cabinets at each side of fireplace is wall space and shall have a receptacle outlet located with in 6' of fire place. Receptacles located inside cabinets do not count. 210.52(C)- Counter top located in pantry shall have receptacles installed so that at no point measured along wall line is more than 24" from a receptacle outlet. 210.70- Required luminaire located at garage man door not working. 314.23(B)(1)- Island receptacle boxes shall not be secured by screws thru side of boxes. 334.30- NM cable shall be secured with in 12" of island receptacle box. 352.30- PVC service riser shall be secured with in 3' of meter base. strap in place but not secured. 406.6- Outdoor receptacle in use cover on east side of garage not completely secured. Missing screw. BCC 9-05-17- It shall be unlawful to block electrical inspectors access to electracal associated with dwelling. Move master bed dresser and bed a minimum of 3' from wall to provide access to receptacles.
|
ELE19-03130
| Electrical Rough-In | 9/23/2019 | 9/24/2019 | 9/24/2019 9:13:04 AM | A | PASS |
|
|
Call Luke with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Clayton Morgan Hardlids rough in ok cover
|