BLD19-00791
| BLD-Final | 10/3/2019 | 10/3/2019 | 10/3/2019 3:34:16 PM | P | PASS |
|
|
access is 9378 Phone #: ###-#### Inspection requested via web by jarrod nelson
|
BLD19-00791
| DOC - Permit Finaled | 10/3/2019 | 10/3/2019 | 10/3/2019 3:34:01 PM | P | PASS |
|
|
|
BLD19-00791
| BLD-Blower Door Test Results | 10/3/2019 | 10/3/2019 | 10/3/2019 3:33:46 PM | P | DONE |
|
|
access is 9378 Phone #: ###-#### Inspection requested via web by jarrod nelson 4.9
|
BLD18-03245
| BLD-Framing/Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 3:02:58 PM | P | PART |
|
|
Robbie Phone #: ###-#### 1st floor common area ok to start ceillings and walls pending reinsp. 2hr shafts elavator and lurndry chase // plm water closet fire stop/ hvac ducts at ceilling/ pending fire stopping applacation listting.
|
BLD19-02383
| BLD-Energy code compliance | 10/1/2019 | 10/3/2019 | 10/3/2019 11:16:07 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by James Jackson missing vappor barrior 2nd floor furred out space. exterior walls.
|
MIS19-00317
| BLD-Conference | 9/26/2019 | 10/3/2019 | 10/3/2019 10:43:48 AM | A | DONE |
|
|
follow up...possible patio cover... no const activity from publicway/ no one home.
|
MIS19-00317
| DOC - Permit Finaled | 10/3/2019 | 10/3/2019 | 10/3/2019 10:43:48 AM | P | PASS |
|
|
no const activity from publicway/ no one home.
|
BLD19-03795
| BLD-Final | 10/2/2019 | 10/3/2019 | 10/3/2019 10:22:40 AM | A | PASS |
|
|
Inspection requested via web by Richard Murray
|
BLD19-03795
| DOC - Permit Finaled | 10/3/2019 | 10/3/2019 | 10/3/2019 10:22:29 AM | P | PASS |
|
|
|
BLD19-01275
| BLD-Framing/Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 10:20:48 AM | A | PASS |
|
|
Please call prior to arrival. If possible to have inspection before 10am. Please ask inspector to call to confirm time for access. Phone #: ###-#### Inspection requested via web by Roy Moore
|
BLD19-03060
| BLD-Framing/Rough-in | 10/1/2019 | 10/3/2019 | 10/3/2019 10:01:01 AM | A | PASS |
|
|
early am requested...thank you Phone #: ###-#### Inspection requested via web by Mark Coiner
|
BLD19-03060
| BLD-Energy code compliance | 10/3/2019 | 10/3/2019 | 10/3/2019 10:00:51 AM | A | PASS |
|
|
early am requested...thank you Phone #: ###-#### Inspection requested via web by Mark Coiner roof and walls insulation complet and aproved.
|
BLD19-01265
| BLD-Framing/Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 9:22:06 AM | A | CANC |
|
|
John Phone #: ###-####
|
BLD19-01265
| BLD-Wall Bracing | 10/3/2019 | 10/3/2019 | 10/3/2019 9:21:40 AM | A | PASS |
|
|
John Phone #: ###-#### room add exterior ok to cover pending straps and hd.
|