Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-01110 BLD-Final5/9/20195/10/20195/10/2019 3:42:32 PMPDONE
Please call two hours ahead to Sandra ###-#### if you can. Phone #: ###-#### Inspection requested via web by BRS Permitting No work needed to strengthen the existing roof structure per engineer’s roof evaluation
BLD19-01110 DOC - Permit Finaled5/10/20195/10/20195/10/2019 3:42:14 PMPPASS
No work needed to strengthen the existing roof structure per engineer’s roof evaluation
BLD18-04570 BLD-Footing5/10/20195/10/20195/10/2019 3:24:53 PMPPASS
late afternoon call half hour before to meet // Milorad Phone #: ###-####-please call so owner can put dog up
BLD18-01791 BLD-Final5/10/20195/10/20195/10/2019 3:02:07 PMPPASS
Omar- please call for access Phone #: ###-####
BLD18-01791 DOC - Permit Finaled5/10/20195/10/20195/10/2019 3:01:57 PMPPASS
BLD18-03527 BLD-Final5/10/20195/10/20195/10/2019 3:01:37 PMPFAIL
Rusty Phone #: ###-#### min 1.5 inches handrail to floor cap.
BLD18-03527 BLD-Blower Door Test Results5/10/20195/10/20195/10/2019 3:01:00 PMPDONE
Rusty Phone #: ###-#### 4.17
BLD19-01099 BLD-Framing/Rough-in5/9/20195/10/20195/10/2019 2:17:48 PMPPASS
Mike Phone #: ###-####
BLD19-00860 BLD-Final5/9/20195/10/20195/10/2019 1:59:00 PMANR
John Phone #: ###-#### fire c/n
BLD19-00317 BLD-Footing5/9/20195/10/20195/10/2019 1:57:13 PMPPART
rebar inspection Phone #: ###-#### Inspection requested via web by chad stradley rebar ok need 3 inches encapulation from ground pending si report of compliance.
BLD19-00926 BLD-Final5/8/20195/10/20195/10/2019 1:56:00 PMPPART
Dave Phone #: ###-#### back dead bolt/ temp ok
BLD19-00277 BLD-Final5/10/20195/10/20195/10/2019 12:08:50 PMPPASS
Kevin Phone #: ###-####
BLD19-00277 DOC - Permit Finaled5/10/20195/10/20195/10/2019 12:08:36 PMPPASS
BLD19-00880 BLD-Wall Bracing5/10/20195/10/20195/10/2019 12:08:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Joe Perdew
BLD19-00197 BLD-Other5/10/20195/10/20195/10/2019 11:46:33 AMPPASS
Bobby-fire rated soffits Phone #: ###-####
BLD19-00197 BLD-Other5/10/20195/10/20195/10/2019 11:46:16 AMPPASS
fire rated soffits
BLD19-01137 BLD-Foundation5/9/20195/10/20195/10/2019 11:02:31 AMAPASS
Jay Phone #: ###-####
BLD19-01122 BLD-Concrete5/8/20195/10/20195/10/2019 10:46:50 AMAPASS
We request a rebar inspection for the in ground spa at Reedhouse prior to shotcrete.

Sincerely,

James T. Thomas
HC Company
###-#### Phone #: ###-#### Inspection requested via web by James Thomas
BLD19-00142 BLD-Framing/Rough-in5/9/20195/10/20195/10/2019 10:23:30 AMAPASS
Rooms 107A, 106A, 148, 131 Phone #: ###-#### Inspection requested via web by Doug Storey
BLD18-02960 BLD-Foundation5/9/20195/10/20195/10/2019 10:06:01 AMAPASS
As early as possible Phone #: 2086970439 >> Inspection requested via mobile web by Charlie Kajkowski rebar ok/ si pending
BLD18-03471 BLD-Wall Bracing5/9/20195/10/20195/10/2019 9:36:40 AMADONE
Phone #: ###-#### Inspection requested via web by Joe Perdew
BLD19-01296 BLD-Final5/7/20195/10/20195/10/2019 8:59:03 AMAPASS
Inspection requested via web by Hans Weikl
BLD19-01296 DOC - Permit Finaled5/10/20195/10/20195/10/2019 8:58:52 AMPPASS
BLD16-02019 BLD-Aging Inspection5/10/20195/10/20195/10/2019 8:58:02 AM PASS
ncfi
BLD16-02019 DOC - Permit Expired5/10/20195/10/20195/10/2019 8:57:47 AMAPASS
ncfi
BLD17-01168 BLD-Aging Inspection5/10/20195/10/20195/10/2019 8:55:47 AM PASS
ncfi
BLD17-01168 DOC - Permit Expired5/10/20195/10/20195/10/2019 8:55:26 AMAPASS
open ele /ncfi
BLD19-00776 BLD-Final5/9/20195/10/20195/10/2019 12:00:00 AMPCANC
Abel Phone #: ###-####