ELE18-02369
| Electrical Rough-In | 1/14/2019 | 1/16/2019 | 1/16/2019 3:07:17 PM | P | PASS |
|
|
1st Floor hardlid areas. Call Joey C. prior to arrival. ###-####. Phone #: ###-#### Inspection requested via web by Scott Campbell Level 1 elevator lobby, clouds, bathrooms hardlids and south stair levels1 to 2 1/2 wall rough in ok cover
|
ELE19-00127
| Electrical Rough-In | 1/15/2019 | 1/16/2019 | 1/16/2019 2:43:11 PM | P | PASS |
|
|
Inspect underground conduit and light pole bases for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud As noted rough in ok cover
|
ELE18-02894
| Final | 1/15/2019 | 1/16/2019 | 1/16/2019 2:05:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Robert Carter 210.12- All outlets located in bedroom areas shall have GFCI protection. 314.25- All boxes shall have covers. HVAC control switch in hallway.
|
ELE19-00184
| Rough-In Permanent Service | 1/16/2019 | 1/16/2019 | 1/16/2019 1:32:44 PM | P | FAIL |
|
|
The ceiling in the bottom of the garage stairs will be furred down so its flat, we have 2 can lights and a smoke detector/ CO2 combo going in there when the fur down is done Phone #: ###-#### Inspection requested via web by Bob Glenn 210.52(A)- In habitable rooms no point measured along floor line shall be more than 6' from a receptacle outlet. Up rec room 13' between receptacle outlets. 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Top of house stair in be at floor level marked with X and at bottom of house stair above switches where drill at 45 degree angle.
|
ELE18-03442
| Final | 1/15/2019 | 1/16/2019 | 1/16/2019 11:38:23 AM | A | PASS |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE18-01608
| Electrical Rough-In | 1/15/2019 | 1/16/2019 | 1/16/2019 10:38:04 AM | A | PASS |
|
|
Inspect underground conduit for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud West branch circuit underground rough in ok cover
|
ELE18-01935
| Electrical Rough-In | 1/15/2019 | 1/16/2019 | 1/16/2019 9:38:08 AM | A | PASS |
|
|
Units 211 , 212 , 213 , 214 , 215 and partials for patio cover units 312 , 314 , 412 , 414 Phone #: ###-#### Inspection requested via web by Tom Betty Patios only on 312, 314, 412, 414 and full units on other noted rough in ok cover.
|
ELE18-03393
| Final | 1/15/2019 | 1/16/2019 | 1/16/2019 8:34:55 AM | A | PASS |
|
|
Can we do this one at 7:30? Before clinical staff start work. Phone #: ###-#### Inspection requested via web by Mark M Final ok
|