Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01406 Conference1/2/20201/2/20201/2/2020 4:06:55 PMPDONE
Contact John about a work around for getting a final without site bench lighting and USB nightstand receptacles installed. Separate permitting possibly? The General Contractor wants in on the conversation. Available after 1:00 p.m. today. Phone #: ###-#### Inspection requested via web by Tom Betty
Discussed with Heather, (project manager with ESI) that all electrical items listed on building permit shall be completed, (site work), prior to issuing a final. All wiring shall be safe for areas that public will have access, (site work). Each room has a piece of furniture with a USB and 120 volt boxless receptacles that according to cut sheet is assembled and installed in furniture at factory and plugs into a wall receptacle. Hoping to verify listing by 1-20-20.
IECC 2015 C408.3.1- Lighting system functional testing. Prior to passing final inspection, the registered design professional shall provide evidence that the lighting control systems have been tested to ensure that the control hardware and software are calibrated, adjusted, programmed, and in proper working condition with construction documents and manufacturers instructions.
ELE20-00015 Electrical Rough-In1/2/20201/2/20201/2/2020 1:23:57 PMPPASS
Walls inspection only. 2nd Floor. Off elevator turn right through double doors. Go right in reception area. New walls are in the break room. There is a print on the reception desk. Phone #: ###-#### Inspection requested via web by Dean Gernaat Walls to north of reception have no electrical, south walls rough in ok cover
ELE19-00602 Permanent Service1/1/20201/2/20201/2/2020 11:33:51 AMAPASS
Permanent service. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
Main service and fire pump service ok
p/s u/g n ok
ELE19-00601 Electrical Rough-In1/1/20201/2/20201/2/2020 11:32:43 AMAPASS
Cover for the 4th floor and 6th floor shear wall. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen Level 4 units 402 thru 424 walls and fire lids, west corridor walls and fire lids, south corridor fire lid rough in ok cover
ELE19-04230 Final12/31/20191/2/20201/2/2020 10:08:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Steven Ragan Final ok
ELE19-04752 Final1/2/20201/2/20201/2/2020 9:47:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Ron Zimmerman Final ok