ELE19-03117
| Electrical Rough-In | 10/1/2019 | 10/1/2019 | 10/1/2019 3:33:51 PM | P | PART |
|
|
Partial rough in Phone #: ###-#### Inspection requested via web by Dave Brueggemann BCC 4-05-23- Warned of 1 siding with drywall prior to electrical inspection. Ordinance states it shall be unlawful to cover wiring or equipment in anyway with out first having same inspected by electrical inspector. Most 1 sided, front bar shall not be covered in anyway prior to inspection. Studios and bathrooms wall and hardlids rough in ok cover.
|
ELE19-03125
| Electrical Rough-In | 9/30/2019 | 10/1/2019 | 10/1/2019 1:59:43 PM | P | PASS |
|
|
John Phone #: ###-#### Bathrooms walls and hardlids rough in ok cover.
|
ELE18-04501
| Final | 10/1/2019 | 10/1/2019 | 10/1/2019 1:20:56 PM | P | FAIL |
|
|
code for front door 1987 Phone #: ###-#### Inspection requested via web by Dan Rohl 110.3- Entry receptacle on stair wall not hot. 314.16- Boxes shall have adequate cubic space for wiring and device installed. 8 cubic inch box with 11 cubic inches of wiring and device installed. Microwave. Informed of new policy not to stage house prior to inspection please.
|
ELE19-03724
| Temporary Service | 10/1/2019 | 10/1/2019 | 10/1/2019 12:05:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE19-03725
| Temporary Service | 10/1/2019 | 10/1/2019 | 10/1/2019 11:55:47 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE19-03726
| Temporary Service | 10/1/2019 | 10/1/2019 | 10/1/2019 11:35:43 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE19-03693
| Electrical Rough-In | 9/30/2019 | 10/1/2019 | 10/1/2019 10:57:38 AM | A | PASS |
|
|
Under floor raceway and floor box. Dan Hommel Phone #: ###-#### Inspection requested via web by Brad Hoots Items noted for front office rough in ok cover
|
ELE18-04645
| Final | 9/30/2019 | 10/1/2019 | 10/1/2019 10:15:54 AM | A | FAIL |
|
|
Geoff Hannaford is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce 110.26(D)- Illumination shall be provided for all work spaces about panel boards. Vanilla spaces need illumination for panels. *ELE18-04645 is attached to BLD18-01882 shell permit. Informed on 12-11-18 that seperate permit needed for other BLD18-03045. No action taken as of 10-1-19. Unable to final until proper permits in place.
|
ELE19-02034
| Final | 9/30/2019 | 10/1/2019 | 10/1/2019 9:14:55 AM | A | PASS |
|
|
Call 30 minutes in advance if possible. Phone #: ###-#### Inspection requested via web by Steve McCloy Flex hanging in hallway are the feeds to rooftop units...OK rest of removed and terminated in boxes. Final ok
|