ELE10-01289 ELE-Aging Inspection10/15/201410/15/201410/15/2014 4:09:10 PM DONE
Still under construction
ELE14-01775 Electrical Rough-In10/15/201410/15/201410/15/2014 3:45:33 PMPPASS
Brian Phone #: ###-#### Library grid rough in ok cover
ELE14-02818 Final10/13/201410/15/201410/15/2014 3:13:52 PMPFAIL
JR Phone #: ###-#### 406.4(D)- All grounding type receptical outlets shall be GFCI protected that are installed on ungrounded circuits. refrigerator.
406.6- All receptical outlets and switches shall have covers. Receptical in bed room shall be tight to box and covered.
Corrections not complete.
Contact A-1 electric. Permit # ele14-01322 for items outside kitchen. Previous contractor no longer working on project. This permit for kitchen only. This contractor to make sure covers are install and recepticals secured to box in bed.
ELE14-02874 Final10/15/201410/15/201410/15/2014 3:10:13 PMPPASS
Storm blew down service mast. ###-#### Mitch Final ok
ELE14-02874 Permanent Service10/15/201410/15/201410/15/2014 3:10:04 PMPPASS
Storm blew down service mast. ###-#### Mitch p/s o/h rec ok
ELE14-02856 Temporary Service10/14/201410/15/201410/15/2014 2:30:15 PMPPASS
Please call me if there''s an issue, thank you Phone #: ###-#### Inspection requested via web by Robert Schroder t/s o/h n ok
ELE14-02862 Permanent Service10/15/201410/15/201410/15/2014 1:35:59 PMPFAIL
ACCESS CODE 6500

Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren 250.53(D)(1)(2)- Metal Underground Water Pipe. If used as a grounding electrode, metal underground water pipe shall meet the requirements of 250.53(D)(1) and (D)(2). (1) Continuity. Continuity of the grounding path or the bonding connection to interior piping shall not rely on water meters or filtering devices and similar equipment. (2) Supplemental Electrode Required. A metal underground water pipe shall be supplemented by an additional electrode of a type specified in 250.52(A)(2) through (A)(8). Clamp loose on poping system and con not verify additional rod wire is under deck
ELE14-01927 Final10/14/201410/15/201410/15/2014 12:58:25 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE14-02868 Temporary Service10/15/201410/15/201410/15/2014 12:34:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman t/s u/g n ok
ELE14-02855 Final10/14/201410/15/201410/15/2014 12:17:07 PMPCANC
Phone #: ###-#### Inspection requested via web by David Nelson Needed rough in inspection
ELE14-02855 Electrical Rough-In10/15/201410/15/201410/15/2014 12:16:57 PMPPASS
Phone #: ###-#### Inspection requested via web by David Nelson Master floor heat rough in ok cover
ELE14-01733 Final10/14/201410/15/201410/15/2014 11:24:20 AMAPASS
code 1905 Phone #: ###-#### Inspection requested via web by kevin blackmon Final ok
ELE14-02004 Final10/15/201410/15/201410/15/2014 10:46:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Brandon Blackham Final ok
ELE14-02857 Electrical Rough-In10/14/201410/15/201410/15/2014 10:15:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Brad Girard Kitchen, washer/dryer, and dining lighting Rough in ok cover
ELE14-01526 Final10/14/201410/15/201410/15/2014 9:38:46 AMAPASS
Please call ahead for access - Richard Phone #: ###-#### Final ok
ELE14-02848 Electrical Rough-In10/14/201410/15/201410/15/2014 9:13:53 AMAPASS
Inspection Request for 2 underground conduit runs. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence underground to pump locations and pole to west rough in ok cover
ELE14-02209 Final10/15/201410/15/201410/15/2014 8:54:25 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
ELE14-02800 Rough-In Permanent Service10/15/201410/15/201410/15/2014 8:49:11 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok 5 Meters