ELE19-03829
| Electrical Rough-In | 10/17/2019 | 10/17/2019 | 10/17/2019 2:43:26 PM | P | PASS |
|
|
Rough-in inspection for the lightning protection ground loop Contact Shawn Evins Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Lightning arrest ground ring complete west, south, east sides. Still open from crane base to about 20' in from west corner. West side rough in ok cover.
|
ELE19-03215
| Final | 10/17/2019 | 10/17/2019 | 10/17/2019 1:51:47 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 210.8(B)- All single phase receptacles up to 50 amp located with in 6' of a sink shall have GFCI protection. Dryer receptacle. 300.11- All cables shall not be supported by grid. Bicycle room LV cables added after ceiling inspection. 330.12- Exposed MC cable installed where subject to physical damage shall be protected from damage. Patches in laundry and S.W. room and reception. 330.30- Support MC in laundry ceiling. TCO ok for moving in equipment only. Washer and dryer receptacles shall remain accessible.
|
MIS19-00225
| ELE-Final | 10/17/2019 | 10/17/2019 | 10/17/2019 1:42:33 PM | P | PART |
|
|
Work completed under ELE19-01088. ELE Final ok
|
ELE19-02169
| Final | 10/17/2019 | 10/17/2019 | 10/17/2019 1:40:14 PM | P | CANC |
|
|
CONTACT: CINDY WOLFE Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden
|
ELE19-03543
| Electrical Rough-In | 10/16/2019 | 10/17/2019 | 10/17/2019 11:26:02 AM | A | PASS |
|
|
Ceiling Rough-in Phone #: ###-#### Inspection requested via web by Kevin Perez Ceiling rough in ok cover.
|
ELE19-03679
| Final | 10/14/2019 | 10/17/2019 | 10/17/2019 10:48:29 AM | A | PASS |
|
|
220V Spa Circuit ; Connection , 50A Spa Sub Panel Phone #: ###-#### Inspection requested via web by Louis Keller Final ok
|
ELE19-03679
| Electrical Rough-In | 10/17/2019 | 10/17/2019 | 10/17/2019 10:48:17 AM | P | PASS |
|
|
220V Spa Circuit ; Connection , 50A Spa Sub Panel Phone #: ###-#### Inspection requested via web by Louis Keller All surface mount to pad with slate pavers. Rough in ok
|
ELE19-03152
| Electrical Rough-In | 10/16/2019 | 10/17/2019 | 10/17/2019 10:22:13 AM | A | PASS |
|
|
Floor heat. Garage code 0713 Phone #: ###-#### Inspection requested via web by Emmet Bushman Master bath floor heat rough in ok cover
|
ELE19-03702
| Rough-In Permanent Service | 10/16/2019 | 10/17/2019 | 10/17/2019 10:00:54 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas 314.25- Recess can junction box covers shall be installed to totally enclose box as per manufacturers instructions. Master hall can, master bed can, kitchen can back junction box covers not flush with box. * Complete dry sheeting ASAP! It is raining at time of inspection.
|
ELE19-01340
| Final | 10/16/2019 | 10/17/2019 | 10/17/2019 9:29:52 AM | A | NH |
|
|
gc 0588 Phone #: ###-#### Inspection requested via web by Heath Thomas No access to interior of house. interior garage door locked as well as all other doors. Recall.
|