Inspections for the day of: Friday, October 18, 2019.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02808 Electrical Rough-In10/17/201910/18/201910/18/2019 3:15:55 PMPPASS
Walls for cover Phone #: ###-#### Inspection requested via web by Mike McCarrel Walls and hardlids marked on contractor print rough in ok cover
ELE19-01406 Electrical Rough-In10/18/201910/18/201910/18/2019 1:48:46 PMPPASS
Contact John M. for rough in above ceiling work. Phone #: ###-#### Inspection requested via web by Tom Betty
As per BCC 4-05-23- It shall be unlawful to cover any wiring or equipment in anyway until the same has first been inspected by an electrical inspector. Boarders were done in area A. Future cover prior to inspection will be required to be removed completely.
Area A grid rough in ok cover
ELE19-03965 Conference10/17/201910/18/201910/18/2019 11:08:42 AMAPASS
Please call first Phone #: ###-#### Inspection requested via web by James Munn
Existing shed with power from previous installation ELE14-01309 which may have been finaled without looking at shed just hot tub. Shed is missing a required disconnecting means.
Owners scope of work is to junction and add disconnecting at box where power emerges from earth, Feed interior 2 receptacles and add an outdoor receptacle off line side of interior GFCI device to reduce nuisance tripping.
Discussed proteciton of interior wiring, TR and WR receptacles, in use covers, outdoor rating of boxes and cover and sealing outer wall. Pamphlet given, owner has a good under standing of scope of work.
ELE19-03749 Electrical Rough-In10/17/201910/18/201910/18/2019 10:24:56 AMAPASS
Contact: Jasper McGrew Phone #: ###-#### Inspection requested via web by Deb Gooden
Discussed 210.71- requirements for conference rooms 215 square foot and larger needing floor receptacles and a minimum number of receptacle outlets. larger conference rm 396 sq.ft. 1/2 walls rough in ok cover.
ELE19-03722 Electrical Rough-In10/17/201910/18/201910/18/2019 9:47:07 AMAPASS
2nd floor inspection; New bar and sound booth for cover. Phone #: ###-#### Inspection requested via web by Steve McCloy
Areas noted, walls complete except for fire condiuts which will be done by fire contractor. Walls noted rough in ok cover
ELE19-02169 Final10/17/201910/18/201910/18/2019 9:27:46 AMAPASS
on site contact Cindy Wolff Phone #: ###-#### Inspection requested via web by Deb Gooden Final ok