ELE16-02979
| ELE-Aging Inspection | 11/27/2019 | 11/27/2019 | 11/27/2019 2:22:57 PM | | FAIL |
|
|
Waiting on contractor
|
ELE19-02541
| Rough-In Permanent Service | 11/21/2019 | 11/27/2019 | 11/27/2019 1:55:08 PM | P | NR |
|
|
This is for a Service/rough-in - please contact Jake with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Deb Morton Due to delays unable to complete work. See rough in and conference.
|
ELE19-02541
| Conference | 11/27/2019 | 11/27/2019 | 11/27/2019 1:52:35 PM | P | PASS |
|
|
This is for a Service/rough-in - please contact Jake with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Deb Morton Discussed requirement for service. 230.6- Service entrance conductors shall be considered outside of building. 230.70(A)(1)- Service disconnecting means shall be located outside of building or immediately upon enterance of the service entrance conductors. 250.50- All grounding electodes present at each building or structure shall be bonded together to form the grounding electrode system. Informed foreman as long as minimum grounding electrodes needed we would grant permenant service however all present will be needed for final. An exterior or interior immediately on inside service disconnecting means was not on one line drawing of print created questions.
|
ELE19-02541
| Electrical Rough-In | 11/27/2019 | 11/27/2019 | 11/27/2019 1:40:15 PM | P | PASS |
|
|
This is for a Service/rough-in - please contact Jake with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Deb Morton Foyer and electrical room walls and hardlids rough in ok cover.
|
ELE19-04444
| Rough-In Permanent Service | 11/26/2019 | 11/27/2019 | 11/27/2019 12:36:06 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE19-03763
| Electrical Rough-In | 11/25/2019 | 11/27/2019 | 11/27/2019 11:21:58 AM | A | PASS |
|
|
Stephen Phone #: ###-#### Kitchen cabinet layout did not change on range, sink, and bar areas. Informed will need extension rings for boxes 1/4" or more from tile surface. Kitchen rough in ok
|
ELE19-01582
| Electrical Rough-In | 11/26/2019 | 11/27/2019 | 11/27/2019 10:54:40 AM | A | PASS |
|
|
Exterior Walls Rough-in. Please contact Brett Jenkins. Phone #: ###-#### Inspection requested via web by Deb Morton Interior walls added to exterior request. Walls only rough in ok cover.
|
MIS19-00405
| ELE-Final | 11/27/2019 | 11/27/2019 | 11/27/2019 10:13:28 AM | P | PASS |
|
|
Waiting for 1 special order cover plate then will call for an inspection on ELE19-04610. MIS Final ok
|
MIS19-00405
| ELE-Conference | 11/27/2019 | 11/27/2019 | 11/27/2019 10:11:59 AM | P | PASS |
|
|
Permit ELE19-04610 has been pulled for kitchen work noted on building permit plan mod.
|
ELE19-03585
| Final | 11/27/2019 | 11/27/2019 | 11/27/2019 10:09:36 AM | P | PART |
|
|
All exterior safed off, dining room TCO ok
|
ELE19-03509
| Electrical Rough-In | 11/26/2019 | 11/27/2019 | 11/27/2019 10:04:21 AM | A | PASS |
|
|
Matt Garcia ###-#### Phone #: ###-#### Inspection requested via web by Jeremy Cloud Riser room switch wall, south wall pack, up parapet receptacles in walls rough in ok cover
|