ELE19-02715
| Electrical Rough-In | 11/5/2019 | 11/6/2019 | 11/6/2019 3:05:54 PM | P | PASS |
|
|
Bill Peace is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Office and corridor grid rough in ok cover.
|
ELE19-03174
| Final | 11/5/2019 | 11/6/2019 | 11/6/2019 2:47:00 PM | P | PASS |
|
|
Please call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
|
ELE19-04271
| Electrical Rough-In | 11/5/2019 | 11/6/2019 | 11/6/2019 1:28:36 PM | A | PASS |
|
|
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Storage room on west side that need boxes installed for lights on west wall. Service not ready. House rough in ok cover
|
ELE19-04209
| Temporary Service | 11/5/2019 | 11/6/2019 | 11/6/2019 12:35:24 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE19-02966
| Final | 11/5/2019 | 11/6/2019 | 11/6/2019 12:31:16 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Icon Electric Final ok
|
MIS19-00364
| ELE-Conference | 11/6/2019 | 11/6/2019 | 11/6/2019 12:16:43 PM | P | FAIL |
|
|
Had an electrical inspection for change out of lighting fixtures and all devices. Electrical contractor stated wall work was being done due to damage caused by renters. Had complaint by drive by neighbor stating interior walls were removed around kitchen area opening up floor plan. Some cabinetry new due to damage according to electrical contractor who also stated he went through every electrical connection in house trouble shooting flickering issue.
|
ELE19-04278
| Final | 11/6/2019 | 11/6/2019 | 11/6/2019 12:10:25 PM | A | FAIL |
|
|
We Went On A Service Call For Blinking Lights And Found Broken Devices And Light Fixtures Ended Up With A Failed Split Bus Panel Changed All Device Made Safe And Installed New Sub Panel! Code Is 2005 On Lock Box Thanks Dave Call Me Please Phone #: ###-#### Inspection requested via web by jason shifflett 210.8(A)- All 15 and 20 amp 120 volt receptacle outlets installed in a garage shall have GFCI protection. Washer and garage door opener. 250.24(A)(5)- Grounded conductor shall not be connected to non-current carrying metal parts on load side of service disconnecting means. Remove main bonding jumper screw. 406.4(D)(4)- Receptacle replacements shall have AFCI protection. Check MIS10-00364- Had complaint from a concerned neighbor of walls removed in kitchen area without a building permit of inspections. House finished and staged.
|
ELE19-04238
| Rough-In Permanent Service | 11/5/2019 | 11/6/2019 | 11/6/2019 10:19:13 AM | A | FAIL |
|
|
Unoccupied. Lock box on back door code 4810 Phone #: ###-#### Inspection requested via web by Ryan Wake 250.53(A)(2)- Unable to verify supplemental ground rod, covered by pavers. 300.4- nail plates needed in bedroom north west corner. BCC 4-05-32- No code violation to be retained. Existing NM cables run through short pieces of PVC with ends open with exposed NM cable. 334.12- NM cable shall not be installed outdoors or tun in exterior conduits, wet or damp locations. NM cable shall not be installed where subject to physical damage, back patio, carport, inside of back door.
|