Inspections for the day of: Wednesday, November 6, 2019.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02715 Electrical Rough-In11/5/201911/6/201911/6/2019 3:05:54 PMPPASS
Bill Peace is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce
Office and corridor grid rough in ok cover.
ELE19-03174 Final11/5/201911/6/201911/6/2019 2:47:00 PMPPASS
Please call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez
Final ok
ELE19-04271 Electrical Rough-In11/5/201911/6/201911/6/2019 1:28:36 PMAPASS
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
Storage room on west side that need boxes installed for lights on west wall. Service not ready. House rough in ok cover
ELE19-04209 Temporary Service11/5/201911/6/201911/6/2019 12:35:24 PMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE19-02966 Final11/5/201911/6/201911/6/2019 12:31:16 PMAPASS
Phone #: ###-#### Inspection requested via web by Icon Electric Final ok
MIS19-00364 ELE-Conference11/6/201911/6/201911/6/2019 12:16:43 PMPFAIL
Had an electrical inspection for change out of lighting fixtures and all devices. Electrical contractor stated wall work was being done due to damage caused by renters.
Had complaint by drive by neighbor stating interior walls were removed around kitchen area opening up floor plan. Some cabinetry new due to damage according to electrical contractor who also stated he went through every electrical connection in house trouble shooting flickering issue.
ELE19-04278 Final11/6/201911/6/201911/6/2019 12:10:25 PMAFAIL
We Went On A Service Call For Blinking Lights And Found Broken Devices And Light Fixtures Ended Up With A Failed Split Bus Panel Changed All Device Made Safe And Installed New Sub Panel! Code Is 2005 On Lock Box Thanks Dave Call Me Please Phone #: ###-#### Inspection requested via web by jason shifflett
210.8(A)- All 15 and 20 amp 120 volt receptacle outlets installed in a garage shall have GFCI protection. Washer and garage door opener.
250.24(A)(5)- Grounded conductor shall not be connected to non-current carrying metal parts on load side of service disconnecting means. Remove main bonding jumper screw.
406.4(D)(4)- Receptacle replacements shall have AFCI protection.
Check MIS10-00364- Had complaint from a concerned neighbor of walls removed in kitchen area without a building permit of inspections. House finished and staged.
ELE19-04238 Rough-In Permanent Service11/5/201911/6/201911/6/2019 10:19:13 AMAFAIL
Unoccupied. Lock box on back door code 4810 Phone #: ###-#### Inspection requested via web by Ryan Wake
250.53(A)(2)- Unable to verify supplemental ground rod, covered by pavers.
300.4- nail plates needed in bedroom north west corner.
BCC 4-05-32- No code violation to be retained. Existing NM cables run through short pieces of PVC with ends open with exposed NM cable.
334.12- NM cable shall not be installed outdoors or tun in exterior conduits, wet or damp locations. NM cable shall not be installed where subject to physical damage, back patio, carport, inside of back door.