Inspections for the day of: Friday, November 8, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02716 Final11/7/201911/8/201911/8/2019 2:41:18 PMPFAIL
Please call before you get there so I can have the owner meet you there and let you in.
Thanks,
Dustin Phone #: ###-#### Inspection requested via web by Dustin Kuester
No access locked. Keys did not work on garage.
ELE18-03750 Final11/7/201911/8/201911/8/2019 2:40:18 PMPFAIL
Please call before you get there so I can have the owner meet you there and let you in.
Thanks,
Dustin Phone #: ###-#### Inspection requested via web by Dustin Kuester
440.6- Ampacity for AC unit shall be in range shown on nameplate. 26 min., 45 max. 20 amp installed.
* No access due to locked doors on garage and signs stating stairs being painted to basement.
Mother in laws quarter and main floor and upstairs all checked ok
ELE15-03756 Final11/7/201911/8/201911/8/2019 2:17:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder
Final sticker in place from Rex Boyles dated 12-1-15. Final ok
ELE19-04304 Final11/7/201911/8/201911/8/2019 1:40:27 PMPFAIL
Added circuit for split unit Phone #: ###-#### Inspection requested via web by David Kubik
210.63- A receptacle outlet shall be located within 25' of new mini split unit
ELE19-04220 Rough-In Permanent Service11/8/201911/8/201911/8/2019 1:11:26 PMPPASS
Phone #: ###-#### Inspection requested via web by Bonnie Page
Rough in ok cover p/s u/g n ok
ELE19-03364 Final11/8/201911/8/201911/8/2019 12:07:18 PMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk
Final ok
ELE19-03274 Final11/8/201911/8/201911/8/2019 11:44:02 AMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk
Final ok
ELE19-01927 Final11/7/201911/8/201911/8/2019 10:56:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
No card posted. Final ok
ELE19-03469 Final11/7/201911/8/201911/8/2019 10:33:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Card signed at door. Final ok
ELE19-03529 Electrical Rough-In11/8/201911/8/201911/8/2019 10:32:38 AMPNH
On site from 8:45am to 9am. Due to busy schedule unable to wait longer. Recall when on site.
ELE19-02028 Final11/7/201911/8/201911/8/2019 10:29:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton

No card posted. Final ok
ELE19-03665 Final11/8/201911/8/201911/8/2019 10:28:04 AMPPASS
Final ok
ELE19-04268 Temporary Service11/7/201911/8/201911/8/2019 9:33:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt t/s u/g n ok
ELE19-03529 Electrical Rough-In11/7/201911/8/201911/8/2019 7:53:31 AMACANC
Requesting 9:00 am inspection time. Phone #: ###-#### >> Inspection requested via web by Ken Olsen Inspection cancelled from web by: Ken Olsen