ELE13-00382
| ELE-Aging Inspection | 12/17/2014 | 12/17/2014 | 12/17/2014 3:26:02 PM | | DONE |
|
|
Still under construction
|
ELE14-03457
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 3:10:09 PM | P | PASS |
|
|
Need UFER Ground inspection Phone #: ###-#### Inspection requested via web by Alan Lusk Concrete encased electrode rough in ok cover
|
ELE14-03435
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 2:26:47 PM | P | PART |
|
|
Jerry Phone #: ###-#### Existing sub panel at shop feeders enter through individual knock outs and ground has not been established. Contractor to correct sub feed and grounding by final. Solar rough in ok
|
ELE14-02796
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 1:49:14 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Office and bathroom walls and hard lid rough in ok cover
|
ELE14-03473
| Final | 12/16/2014 | 12/17/2014 | 12/17/2014 1:04:07 PM | P | FAIL |
|
|
We Are Changing A meter Socket And Extending The Riser For A Future Remodel Should Be Done Around Noon Phone #: ###-#### Inspection requested via web by jason shifflett 240.24(D)- Overcurrent devices shall not be located in the vicinity of easily ignitable materials such as clothes closets. 110.26- Flat platform work space 30" wide and 36" deep shall be in front of meter base. 4-05-32- Code violations not to be retained.
|
ELE14-03473
| Permanent Service | 12/17/2014 | 12/17/2014 | 12/17/2014 1:03:57 PM | P | PASS |
|
|
We Are Changing A meter Socket And Extending The Riser For A Future Remodel Should Be Done Around Noon Phone #: ###-#### Inspection requested via web by jason shifflett Reconnect on temporary basis due to cold time of year. Refer to final for notes. p/s o/h rec ok
|
ELE14-03260
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 12:25:34 PM | P | PASS |
|
|
Ryan Phone #: ###-#### Underground from sidewalk to ground box at west picnic area rough in ok cover
|
ELE14-03471
| Temporary Service | 12/16/2014 | 12/17/2014 | 12/17/2014 11:42:35 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL 110.12(A)- Unused openings shall be closed. 110.27- Live parts shall be guarded against accidental contact. Secure panel cover. 590.6(B)- Recepticals other than 120 volt shall have GFCI protection
|
ELE14-02431
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 11:08:05 AM | P | PASS |
|
|
Wes ###-#### Refer to ele14-01595 for underground portion of job. Grid rough in for office 127 rough in ok cover.
|
ELE14-01595
| Electrical Rough-In | 12/16/2014 | 12/17/2014 | 12/17/2014 11:06:54 AM | A | CANC |
|
|
Contact: Wes Powell... ceiling inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden This permit for underground portion of job. Refer to ele14-02431
|
ELE13-03105
| Electrical Rough-In | 12/16/2014 | 12/17/2014 | 12/17/2014 10:21:42 AM | A | PASS |
|
|
Entry bathroom walls Phone #: ###-#### Inspection requested via web by matt miller Rough in ok cover
|
ELE14-03420
| Electrical Rough-In | 12/16/2014 | 12/17/2014 | 12/17/2014 9:37:03 AM | A | PASS |
|
|
fire caulking will be complete in the a.m. Phone #: ###-#### Inspection requested via web by Emmet Bushman Rough in ok cover
|
ELE14-03420
| Permanent Service | 12/17/2014 | 12/17/2014 | 12/17/2014 9:28:29 AM | P | PASS |
|
|
fire caulking will be complete in the a.m. Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s u/g n ok
|
ELE14-02464
| Final | 12/16/2014 | 12/17/2014 | 12/17/2014 9:15:01 AM | A | PASS |
|
|
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson Final ok
|
ELE14-02596
| Final | 12/16/2014 | 12/17/2014 | 12/17/2014 8:55:47 AM | A | FAIL |
|
|
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson 110.7- Wiring integrity. Master bath vanity receptical outlet not working. Dead 300.15- Powder bath lighting outlet shall have box and cover. 406.5- Master vanity receptical outlets shall have covers. 410.16- Closet luminaires that can have incandescent lamps installed shall clear shelf by 12" minimum. up bed closets. 440.6- AC max overcurrent device shall not exceed that on name plate. 30 amp installed on 25 amp max.
|