ELE17-03971
| ELE-Aging Inspection | 12/3/2019 | 12/3/2019 | 12/3/2019 3:56:11 PM | | FAIL |
|
|
No inspection history. Called contractor and left message.
|
ELE19-04631
| Electrical Rough-In | 12/3/2019 | 12/3/2019 | 12/3/2019 3:52:47 PM | P | FAIL |
|
|
ADU on Southwest corner of lot. Key is on top of fence post if it’s locked. Call with any questions. Thank you Phone #: ###-#### Inspection requested via web by Eric Brown Spoke with plans examiner who stated with wall being added for sleeping area a building permit is required.
|
ELE19-04557
| Electrical Rough-In | 12/3/2019 | 12/3/2019 | 12/3/2019 3:41:51 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 210.52(A)- No point measured along floor line shall be more than 6' from a receptacle outlet. Up bed 14' between receptacles, 250.32- Grounding electrodes shall be terminated at detached building disconnecting means not sub-panel. #4 bare. 300.4- Nail plates needed up storage by switch and down bed in closet. 334.30- NM shall be secured at intervals not to exceed 4 1/2'. At least 3 locations.
|
ELE19-03117
| Final | 12/3/2019 | 12/3/2019 | 12/3/2019 2:40:12 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Dave Brueggemann Job not ready. 110.26- Work clearance shall be provided for water heater breaker disconnect. Roof top not complete. Receptacles not working, unable to test all receptacles due to appliances not set yet, Remove kitchen grid, has not been inspected. Allow Electrical contractor to finish job and recall.
|
ELE19-04579
| Electrical Rough-In | 12/2/2019 | 12/3/2019 | 12/3/2019 11:50:21 AM | A | PASS |
|
|
home owner will be there Phone #: ###-#### Inspection requested via web by David McClellan Walls removed to create 1 large open area containing entry, living, kitchen and dining areas. Gas fireplace not in place at time of inspection. Rough in ok cover
|
ELE19-04623
| Electrical Rough-In | 12/2/2019 | 12/3/2019 | 12/3/2019 11:10:03 AM | A | PASS |
|
|
Underground and bonding for swimming pool/spa Phone #: ###-#### Inspection requested via web by Lars Johnson Items noted rough in ok cover
|
ELE19-04504
| Rough-In Permanent Service | 12/2/2019 | 12/3/2019 | 12/3/2019 10:51:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE19-04644
| Electrical Rough-In | 12/2/2019 | 12/3/2019 | 12/3/2019 10:30:46 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt 250.32- A grounding electrode system shall be installed for panel in garage. At time of rough in #6 solid stubs out bottom of panel but does not terminate anywhere. Grounding electrode and grounding electrode conductor shall be inspected prior to cover garage. Basement rough in ok cover
|
ELE19-04615
| Electrical Rough-In | 12/3/2019 | 12/3/2019 | 12/3/2019 9:52:48 AM | A | PASS |
|
|
Walls. Please call ahead cause you’ll need key. Phone #: ###-#### Inspection requested via web by Kevin Burke Attention is required for corridor between this space and elevator lobby. Several open boxes, some have to do with this space and some do not. Unsupported cables, conduits, boxes, exposed wiring hanging out of unused connectors. Area has grid cover in place. Steps must be taken to address safety issues or an MIS permit will be started to ensure repair. Walls only rough in ok cover
|