Inspections for the day of: Monday, February 3, 2020.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02541 Final1/29/20202/3/20202/3/2020 3:25:57 PMPPASS
Electrical Final. Jake is the contact Phone #: ###-#### Inspection requested via web by Deb Morton Final ok
ELE20-00090 Final2/3/20202/3/20202/3/2020 2:44:52 PMPFAIL
Contact: Caleb Burke Phone #: ###-#### Inspection requested via web by Deb Gooden *Address is 802 W. Bannock, need corrected prior to final.
110.14- Unused breaker spaces shall be closed by approved means.
314.25- All boxes shall have covers installed, most removed due to painting.
408.4- Circuit directories shall be present and accurate.
ELE19-00601 Electrical Rough-In2/3/20202/3/20202/3/2020 1:35:42 PMPPASS
Soffit Cover. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
Exterior soffits level 1 rough in ok cover
ELE20-00206 Electrical Rough-In2/3/20202/3/20202/3/2020 12:50:15 PMPPASS
Installed pvc in back yard for garage and main line for idaho power. Phone #: ###-#### Inspection requested via web by David Kubik Underground noted rough in ok cover.
ELE19-01936 Final2/3/20202/3/20202/3/2020 11:35:47 AMAPASS
Please call 30 min ahead Phone #: ###-#### Inspection requested via web by William Andrews
410.10(D)- Suspended luminaire removed in restricted area around bath tub.
Final ok
ELE16-02304 Final2/3/20202/3/20202/3/2020 11:34:05 AMAPASS
Phone #: ###-#### Inspection requested via web by William Andrews Final ok
ELE20-00382 Temporary Service1/31/20202/3/20202/3/2020 11:10:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Richard Gratiot t/s o/h n ok
ELE19-03702 Final1/31/20202/3/20202/3/2020 10:53:22 AMAFAIL
lockbox 1319 Phone #: ###-#### Inspection requested via web by Heath Thomas
110.3- Poder bath receptacles not working.
Master bath floor heat thermostat too close to wall cannot reset GFCI in right side.
314.16- Receptacle installed for kitchen island counter top shall be of sufficient size for conductor allowance installed. 11.25 cubic inches installed in a 8 cubic inch box.
ELE20-00386 Temporary Service2/2/20202/3/20202/3/2020 9:51:43 AMAFAIL
New Temporary service to inspect, questions call Chase- ###-#### Phone #: ###-#### Inspection requested via web by Davin Moore 400.5- Cord conductor shall be large enough for covercurrent device supplying cord. 50 amp. 590.6(B)- GFCI protection shall be provided for all receptacles for temp power Twist lock.
ELE19-04131 Electrical Rough-In1/31/20202/3/20202/3/2020 9:14:02 AMAPASS
Inspect raceways under slab in dining rooms , restaurant and bar areas. Phone #: ###-#### Inspection requested via web by John Mittleider Areas noted plus private dining under slab rough in ok cover.
ELE19-04839 Electrical Rough-In1/31/20202/3/20202/3/2020 8:44:01 AMAPASS
Fritz Phone #: ###-####
Conference room B-20 switches rough in ok cover.