ELE19-00361
| Final | 2/5/2019 | 2/6/2019 | 2/6/2019 2:29:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew White Final ok
|
ELE19-00335
| Conference | 2/6/2019 | 2/6/2019 | 2/6/2019 2:29:43 PM | P | PASS |
|
|
Discusssed if conduit run from disconnect to transformer is required to stay out of work space associated with disconnecting means. As per 110.26- work space shall be clear from floor to 6 1/2' minimum height and minimum width and depth of space depending on voltage in front of disconnecting means.
|
ELE18-04570
| Electrical Rough-In | 2/6/2019 | 2/6/2019 | 2/6/2019 2:06:48 PM | P | PASS |
|
|
rough in cover on first 5 units, 102,104, 106, 202, 204 Phone #: ###-#### Inspection requested via web by mike brown Units noted rough in ok cover
|
ELE19-00408
| Electrical Rough-In | 2/4/2019 | 2/6/2019 | 2/6/2019 1:36:04 PM | P | PASS |
|
|
Contact: Josh Mangum... underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Bar underslab rough in ok cover
|
ELE19-00448
| Electrical Rough-In | 2/6/2019 | 2/6/2019 | 2/6/2019 11:34:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Garage only rough in ok cover
|
ELE19-00155
| Electrical Rough-In | 2/5/2019 | 2/6/2019 | 2/6/2019 11:04:32 AM | A | PASS |
|
|
Dean Hunsperger is the contact person (electrician). He needs an underground inspection. Thank you Phone #: ###-#### Inspection requested via web by A.M.E. Office Concrete encased electrode located on exterior of foundation stubbed out of footing on east side under 2" PVC shall be protected from weather and direct contact with earth. Electrical contractor to encase stub and connection in concrete to protect. Interior and 2" exterior underground rough in ok cover
|
ELE19-00335
| Electrical Rough-In | 2/6/2019 | 2/6/2019 | 2/6/2019 10:26:20 AM | A | PASS |
|
|
The Knitting Factory wall inspection in concert area. Dimitri Gyteas on site contact. Phone #: ###-#### Inspection requested via web by Jim Noll North and south pathway lights and receptacles wall rough in ok cover
|
ELE19-00106
| Electrical Rough-In | 2/4/2019 | 2/6/2019 | 2/6/2019 10:25:21 AM | A | PASS |
|
|
Contact Brian Axelson with any questions. Ceiling Inspection Requested.
Thank you ; have a great day! Phone #: ###-#### Inspection requested via web by JENNY EMEL Grid rough in ok cover
|
ELE19-00165
| Final | 2/5/2019 | 2/6/2019 | 2/6/2019 9:16:09 AM | A | CANC |
|
|
Please call prior to arrival for access. Phone #: ###-#### >> Inspection requested via web by Patrick Paz Inspection cancelled from web by: Patrick Paz
|
ELE19-00361
| Final | 2/5/2019 | 2/6/2019 | 2/5/2019 5:49:45 PM | A | CANC |
|
|
inspection you already did and we corrected the exposed wire on other side of house Phone #: ###-#### >> Inspection requested via web by Matthew White Inspection cancelled from web by: Matthew White
|