Inspections for the day of: Tuesday, March 5, 2019.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00335 Final3/5/20193/5/20193/5/2019 3:30:07 PMPCANC
can this please be the last inspection time for the day if possible. thanks Phone #: ###-#### Inspection requested via web by Jim Noll
Jim Noll called and asked to cancel inspection and they would recall. Thanks for heads up.
ELE19-00127 Permanent Service3/5/20193/5/20193/5/2019 3:09:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Jeremy Cloud p/s u/g n ok
ELE18-00240 Final3/5/20193/5/20193/5/2019 2:46:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by David Baker
See RI
ELE18-00240 Electrical Rough-In3/5/20193/5/20193/5/2019 2:17:54 PMPFAIL
Phone #: ###-#### Inspection requested via web by David Baker
Listing and disconnecing means confirmed.
300.3(A)- Single conductors shall be installed in a wiring method recognized in chapter 3 of NEC.
300.18- Raceways shall be installed in complete runs. Exposed single conductors feeding sign through EMT not terminated at sign, wire leaves conduit and enter unbushed opening.
ELE19-00371 Electrical Rough-In3/5/20193/5/20193/5/2019 2:13:53 PMPPASS
Underground inspection please call cody for questions 2084843754q Phone #: ###-#### Inspection requested via web by Shane Lott
Underground fron in ground junctin box to a single light pole rough in ok cover.
ELE18-00082 Final3/5/20193/5/20193/5/2019 1:40:06 PMPPASS
Phone #: ###-#### Inspection requested via web by David Baker Final ok
ELE18-00082 Electrical Rough-In3/5/20193/5/20193/5/2019 1:15:46 PMPPASS
Phone #: ###-#### Inspection requested via web by David Baker
Listing and disconnecting means confirmed, rough in ok cover
ELE19-00702 Temporary Service3/5/20193/5/20193/5/2019 1:14:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE19-00703 Temporary Service3/5/20193/5/20193/5/2019 12:47:14 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE19-00679 Final3/4/20193/5/20193/5/2019 12:13:53 PMANH
Inspection for 20 amp ductless split rough-in and final inspection Phone #: ###-#### Inspection requested via web by shane miller
No answer at door left card
ELE18-04499 Electrical Rough-In3/4/20193/5/20193/5/2019 12:01:45 PMAPASS
Dusty Phone #: ###-####
Corrections complete. bathroom rough in ok cover
ELE19-00090 Final3/5/20193/5/20193/5/2019 11:39:22 AMAPASS
Smoke detectors are now AFCI protected. Phone #: ###-#### Inspection requested via web by Dan Hilke Final ok
ELE18-04101 Final3/4/20193/5/20193/5/2019 11:25:32 AMAPASS
GARAGE CODE 7573 Phone #: ###-#### Inspection requested via web by Bob Glenn
Final ok
ELE19-00758 Electrical Rough-In3/4/20193/5/20193/5/2019 10:34:33 AMAPASS
Underground and bonding for swimming pool/spa.
Underground for: (5) pool lights, (1) spa light, (3) bubbles, (3) sheer descents, (1) autocover motor, (1) autocover key switch
Bonding for: (4) EQ corners, (2) autocover, (1) water, (1) steel/equipment, (1) pergola columns Phone #: ###-#### Inspection requested via web by Lars Johnson
For areas noted rough in ok cover
ELE19-00613 Final3/4/20193/5/20193/5/2019 10:08:48 AMAFAIL
Call Logan with questions. Nobody on site. Everything accessible. Phone #: ###-#### Inspection requested via web by BRS Permitting Still not tight, can turn by hand.
ELE19-00596 Final3/4/20193/5/20193/5/2019 9:43:33 AMAPART
Contact: Rick Badley Phone #: ###-#### Inspection requested via web by Deb Gooden
Down storage/shop area. tco ok
ELE19-00335 Final3/5/20193/5/20193/5/2019 9:39:26 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jim Noll
Corrections not all complete. Open boxes up mech., open boxes above stage floor. (Trouble shooting)