ELE18-04784
| Electrical Rough-In | 3/6/2019 | 3/6/2019 | 3/6/2019 2:41:50 PM | P | PASS |
|
|
Block inspection Phone #: ###-#### Inspection requested via web by Tom Jenkins Block boxes rough in ok cover
|
ELE18-02369
| Electrical Rough-In | 3/5/2019 | 3/6/2019 | 3/6/2019 2:11:51 PM | P | PASS |
|
|
Call Joey Campbell prior to arrival. Fifth floor hardlids. Phone #: ###-#### Inspection requested via web by Scott Campbell Level 5 hardlids in bathrooms and elevator lobby rough in ok cover
|
ELE19-00740
| Rough-In Permanent Service | 3/5/2019 | 3/6/2019 | 3/6/2019 1:41:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE18-01391
| Electrical Rough-In | 3/5/2019 | 3/6/2019 | 3/6/2019 12:55:21 PM | A | PASS |
|
|
East stairwell rough in all levels. Phone #: ###-#### Inspection requested via web by Tom Betty Area noted walls rough in ok cover
|
ELE19-00111
| Electrical Rough-In | 3/5/2019 | 3/6/2019 | 3/6/2019 12:24:25 PM | A | PASS |
|
|
CONTACT PAUL WHEELER Phone #: ###-#### Inspection requested via web by Deb Gooden Office area walls and ceiling rough in ok cover
|
ELE19-00606
| Final | 3/1/2019 | 3/6/2019 | 3/6/2019 11:56:13 AM | A | PASS |
|
|
She will be home by 8:10 AM. If you have any questions please feel free to contact Jared ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Final ok
|
ELE19-00606
| Electrical Rough-In | 3/1/2019 | 3/6/2019 | 3/6/2019 11:55:54 AM | A | PASS |
|
|
She will be home by 8:10 AM. If you have any questions please feel free to contact Jared ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Water heater disconnect rough in ok
|
ELE19-00574
| Final | 3/5/2019 | 3/6/2019 | 3/6/2019 11:42:59 AM | A | PASS |
|
|
Please call 45 minutes ahead of time so I can meet you on site. Thank you! Phone #: ###-#### Inspection requested via web by aaron dill Final ok
|
ELE19-00010
| Final | 3/6/2019 | 3/6/2019 | 3/6/2019 11:01:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE18-04826
| Final | 3/5/2019 | 3/6/2019 | 3/6/2019 10:35:45 AM | A | PASS |
|
|
Garage Code 4224 Press Enter Please contact Mike with any questions or concerns. Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE19-00722
| Electrical Rough-In | 3/5/2019 | 3/6/2019 | 3/6/2019 10:02:07 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Caleb Gaylord 210.52(A)(1)- Receptacle outlets located in pantry shall be on a small appliance branch circuit. 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Several locations through out. 300.15- 14-2 located in ceiling near pantry shall terminate in a box. * Fireplace switch box empty.
|
ELE18-03320
| Final | 3/5/2019 | 3/6/2019 | 3/6/2019 9:18:43 AM | A | NR |
|
|
Please call ahead 30 minutes prior to arrival. Ron is our site contact at ###-#### Phone #: ###-#### Inspection requested via web by Kerri Hamilton All items and areas checked ok. BLD still under review. Unable to document until issued.
|
ELE19-00335
| Final | 3/6/2019 | 3/6/2019 | 3/6/2019 8:49:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Noll Final ok
|