Inspections for the day of: Friday, March 6, 2020.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00602 Final3/6/20203/6/20203/6/2020 3:09:47 PMPPART
Changing out the exits today. Please come as late as possible or call 1/2 prior to arrival. Danny is the contact. Thanks Phone #: ###-#### Inspection requested via web by Buster Bowen Card signed. TCO OK
ELE20-00796 Final3/6/20203/6/20203/6/2020 2:17:41 PMPPASS
The Verizon disconnect on the NE corner traffic pole at the intersection of N. 8th St. ; W. Bannock St. needs a final inspection. The code to the lock is "2914". Please call Joe with any questions or issues ###-####. Phone #: ###-#### Inspection requested via web by Joe McLean
Unable to verify supply, contact explained fed from Idaho Power transformer. #10 equipment grounding conductor installed with a main bonding jumper installed. Final ok
ELE20-00797 Final3/6/20203/6/20203/6/2020 2:15:58 PMPPASS
The Verizon disconnect on the NW corner traffic pole needs a final inspection. The code to the lock is "2914". If there are any questions or issues please call Joe at ###-####. Phone #: ###-#### Inspection requested via web by Joe McLean
Unable to verify supply, contact explained fed from Idaho power transformer. #10 equipment ground installed with main bonding jumper installed at disconnect. Final ok
ELE20-00669 Final3/5/20203/6/20203/6/2020 1:49:46 PMPNR
There will be people there. If you have any questions please feel free to contact Fred ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan See rough in
ELE20-00669 Electrical Rough-In3/5/20203/6/20203/6/2020 1:49:19 PMPFAIL
There will be people there. If you have any questions please feel free to contact Fred ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 110.7- Complete wiring installations shall be free of short circuits. Flash evidence on a roof box connector located just west of north emergency exit. Check for damage.
210.8(B)- Roof top receptacle outlets shall have GFCI protection. Did not trip when tested.
ELE19-04907 Final3/6/20203/6/20203/6/2020 12:51:02 PMPPASS
No card posted. Final ok
MIS20-00004 ELE-Conference2/7/20203/6/20203/6/2020 12:24:26 PMACANC
Check on pneumatic line in panel in US Bank. Rescheduled
ELE20-00783 Final3/5/20203/6/20203/6/2020 12:03:28 PMAPASS
Please call when you are on you way. Phone #: ###-#### Inspection requested via web by Spencer McLean Final ok
ELE20-00783 Electrical Rough-In3/6/20203/6/20203/6/2020 12:02:55 PMPPASS
Please call when you are on you way. Phone #: ###-#### Inspection requested via web by Spencer McLean
MC run fished down walls in areas noted rough in ok.
ELE19-03015 Final3/5/20203/6/20203/6/2020 10:49:47 AMAFAIL
coffee bar & soup cooler ... call ahead // Keegan Phone #: ###-####
300.15- All wiring to terminate in a box by approved means. Under west display added old circuit cut off about 18" out of conduit and left exposed.
ELE20-00594 Final3/5/20203/6/20203/6/2020 9:55:25 AMAPASS
Jose Phone #: ###-#### Final ok
ELE19-04696 Electrical Rough-In3/5/20203/6/20203/6/2020 9:18:11 AMAPASS
Walls and ceiling rough in. Still have to install sub panel on back wall of gazebo and will call for service when done. Thank you Phone #: ###-#### Inspection requested via web by Eric Brown
Structure rough in ok cover.