Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01398 Final4/17/20194/18/20194/18/2019 2:51:08 PMPCANC
APT 707-please call when on the way ###-#### Phone #: ###-#### Inspection requested via web by Same Electric
Needed rough in inspection
ELE19-01398 Electrical Rough-In4/18/20194/18/20194/18/2019 2:50:40 PMPPASS
APT 707-please call when on the way ###-#### Phone #: ###-#### Inspection requested via web by Same Electric
Kitchen area all new rough in ok cover
ELE19-01362 Final4/16/20194/18/20194/18/2019 1:55:53 PMPPASS
Please call Kaden with any questions, please call our office before arriving Phone #: ###-#### Inspection requested via web by William Salts Final ok
ELE19-01362 Electrical Rough-In4/18/20194/18/20194/18/2019 1:42:07 PMPPASS
Please call Kaden with any questions, please call our office before arriving Phone #: ###-#### Inspection requested via web by William Salts
Rough in for work noted ok
ELE18-03100 Final4/17/20194/18/20194/18/2019 12:44:20 PMAPASS
Beth-homeowner called inspection in Phone #: ###-#### Final ok
ELE18-01935 Electrical Rough-In4/17/20194/18/20194/18/2019 11:53:26 AMAPASS
Drop ceilings units 407 , 409 and one planter Call John Phone #: ###-#### Inspection requested via web by Tom Betty
Discussed unit 506 island. Kitchen island shall be a undivided space as per 210.52(C)(4). Area behind sink is greater than 12" in depth so shall be undivided space. A minimum of 1 receptacle outlet could serve island counter top space.
Units noted drop lids and S.E. planter pour rough in ok cover
ELE19-00602 Electrical Rough-In4/17/20194/18/20194/18/2019 11:46:34 AMAPASS
NW Concrete Stairwell rough in. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
Area noted pour rough in ok cover
ELE19-01397 Electrical Rough-In4/17/20194/18/20194/18/2019 10:50:48 AMAFAIL
Justin Metcalf ###-#### or Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
Too many items to list.
ELE19-01153 Rough-In Permanent Service4/17/20194/18/20194/18/2019 9:56:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson
Rough in ok cover p/s u/g n ok
ELE19-01281 Permanent Service4/17/20194/18/20194/18/2019 9:21:58 AMAPASS
Idaho power will be there between 10 to 11am for about thirty minutes to cut power long enough to add a tap.
Call Jed if you have any questions at 1.801.875.3714
Phone #: ###-####
Inspection requested via web by Ryan King
Confirmed grounding electrode system under concrete and listing of polaris taps using.
p/s u/g rec ok