Inspections for the day of: Thursday, April 23, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00855 ELE-Aging Inspection4/23/20154/23/20154/24/2015 3:36:34 PM CANC
too busy
ELE15-00945 Final4/23/20154/23/20154/23/2015 3:47:17 PMPPASS
Robert Phone #: ###-#### Final ok
ELE15-01133 Temporary Service4/23/20154/23/20154/23/2015 3:20:47 PMPPASS
Phone #: ###-#### Inspection requested via web by mark hood t/s o/h n ok
ELE15-00774 Rough-In Permanent Service4/22/20154/23/20154/23/2015 3:12:20 PMPPART
We will be ready by 1:00 or 2:00 PM... I will call around noon to verify our progress. Thank you... Phone #: ###-#### Inspection requested via web by JOHN MCCURDY Will come by next day to confirm make up and dry sheet peak of roof do to storm expected. OK foam seal.
ELE15-01125 Rough-In Permanent Service4/23/20154/23/20154/23/2015 2:24:43 PMPFAIL
Phone #: ###-#### Inspection requested via web by ron spen cer
Idaho Power requires an expansion joint in service riser.
300.4- NM cable shall be protected by nail plates when ran through holes less than 1 1/4" from framing surface or notched wood.
334.23- NM cable shall be protected from physical damage when ran in an accessible attic within 7' of attic access.
110.12(B)- Loose neutral in panel.
ELE15-00944 Final4/23/20154/23/20154/23/2015 1:51:43 PMPFAIL
Robert Phone #: ###-#### 250.132- Short sections of raceway shall be connected to an equipment grounding conductor.
* Heat pump shall be set prior to final.
ELE15-01099 Conference4/22/20154/23/20154/23/2015 1:20:00 PMPDONE
Randall Phone #: ###-#### Discussed remodel of upstairs bathrooms and new kitchen peninsula. New receptacles for peninsula off existing kitchen appliance or new circuit. required 20 amp for bathroom receptacles, closet light placement, floor line receptacles for bed wall.
ELE14-02819 Permanent Service4/23/20154/23/20154/23/2015 12:37:09 PMPPASS
Phone #: ###-#### Inspection requested via web by kendall bender Correction made p/s u/g n ok House panel
ELE15-00757 Final4/23/20154/23/20154/23/2015 12:20:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE15-01113 Electrical Rough-In4/22/20154/23/20154/23/2015 10:54:04 AMAPASS
Contact: Seth Stears. Ceiling cover in kitchen. Phone #: ###-#### Inspection requested via web by Seth Stears Hardlid in new dining area rough in ok cover
ELE15-01095 Electrical Rough-In4/21/20154/23/20154/23/2015 10:10:04 AMAPASS
Contact: Cody Cannon, rough-in, walls only Phone #: ###-#### Inspection requested via web by Deb Gooden Discussed grounding electrodes for new service and posting available fault current before permanent service. Ordered 65k breakers. transformer very close. Wall rough in ok cover
ELE15-01124 Electrical Rough-In4/23/20154/23/20154/23/2015 9:09:33 AMAPASS
Please call David Kubik at ###-#### if needed Phone #: ###-#### Inspection requested via web by Charmel Kubik Kitchen rough in ok cover
ELE15-00931 Rough-In Permanent Service4/22/20154/23/20154/23/2015 8:45:33 AMAPASS
Please contact Cody ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok