Inspections for the day of: Wednesday, May 15, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01415 Final5/14/20195/15/20195/15/2019 3:38:44 PMPFAIL
Phone #: ###-#### Inspection requested via web by Christy Cheney
210.62- Window that can be used for advertising shall have show window receptacles installed. All store front windows. Had verbal with wireman.
ELE19-01459 Final5/15/20195/15/20195/15/2019 3:15:23 PMPFAIL
The lock box code to get inside is 9781 Phone #: ###-#### Inspection requested via web by Jonathan Poot
Unable to locate plans on site. provide and recall
ELE19-01064 Final5/15/20195/15/20195/15/2019 2:47:31 PMPFAIL
Hot tub wiring ready for final. Please call Jason at ###-#### when you are on the way. Thank you Phone #: ###-#### Inspection requested via web by Kelly Felin
680.22(A)(1)- A receptacle outlet shall be located with in 20' of waters edge but no closer than 6' of the spa or hot tub.
680.42(B)(4)- For hot tubs with top rim less than 28" above perimeter surfaces an equipotential bonding of perimeter surfaces is required.
ELE19-00913 Final5/15/20195/15/20195/15/2019 2:14:08 PMPPASS
Jake Phone #: ###-#### Final ok
ELE19-01783 Temporary Service5/14/20195/15/20195/15/2019 1:01:18 PMAPASS
Phone #: ###-#### Inspection requested via web by Heath Thomas t/s u/g n ok
ELE19-01785 Rough-In Permanent Service5/14/20195/15/20195/15/2019 12:40:16 PMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson
Rough in ok cover p/s u/g n ok
ELE19-01483 Conference5/13/20195/15/20195/15/2019 12:00:06 PMAPASS
Phone #: ###-#### Inspection requested via web by Kyle Dillon
Discussed moving overhead fed meterbase off upper level deck to ground level. No changes to be made to interior panel which is split bus 100 amp. Want to locate meter to ground level, run conduit externally to below where original meter located, run up thru deck floor and LB into existing split bus panel. A max of 6 throws exist, ground rods to be added to grounding electrode system.
ELE19-00800 Final5/14/20195/15/20195/15/2019 10:37:47 AMAPASS
Robert Phone #: ###-#### Final ok
ELE19-00800 Electrical Rough-In5/15/20195/15/20195/15/2019 10:37:26 AMPPASS
Robert Phone #: ###-####
Heat pump rough in ok
ELE19-00934 Final5/14/20195/15/20195/15/2019 10:11:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Steven Ragan Final ok
ELE19-01648 Electrical Rough-In5/13/20195/15/20195/15/2019 9:51:07 AMAPASS
Wall cover Phone #: ###-#### Inspection requested via web by David Feller
Misc walls through out added for dividing wall and offices rough in ok cover
ELE19-01406 Electrical Rough-In5/14/20195/15/20195/15/2019 9:37:45 AMAPASS
Contact John for area A level 1 walls. Phone #: ###-#### Inspection requested via web by Tom Betty
A1 sec. 1 top out 3 1/2' walls only rough in ok cover
ELE19-01652 Electrical Rough-In5/14/20195/15/20195/15/2019 9:06:12 AMAPASS
Requesting 9:00 am inspection time Replace existing lighting in pole sign to new led lighting. Phone #: ###-#### Inspection requested via web by Ken Olsen
Listings confirmed. Rough in ok