ELE19-01486
| Permanent Service | 5/2/2019 | 5/2/2019 | 5/2/2019 2:44:38 PM | P | PASS |
|
|
Changing out meter/panel box. IPCO is requiring inspection before they will re-energize. This is an occupied residence. Can you please arrange to inspect latter this afternoon so power can be restored today, thanks. Phone #: ###-#### Inspection requested via web by Brandon Winters p/s o/h rec ok
|
ELE19-00831
| Final | 5/1/2019 | 5/2/2019 | 5/2/2019 2:02:32 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Final ok
|
ELE18-04652
| Final | 5/1/2019 | 5/2/2019 | 5/2/2019 1:21:59 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Stewart For electrical final inspection all covers must be installed, devices operational, and exposed wiring below 8' shall be protected from accidental contact. All device wiring checked out ok, Wall cover for fireplace build out not installed with exposed wiring all around fireplace. Recall when all wall cover and device covers installed and ready to use.
|
ELE19-01583
| Temporary Service | 5/1/2019 | 5/2/2019 | 5/2/2019 11:50:59 AM | A | FAIL |
|
|
temporary service for construction site. Shannon is the contact person. Phone #: ###-#### Inspection requested via web by Shawna Gates 210.21- Overcurrent protection shall not axceed rating of receptacle. 40 amp installed. 590.6- All receptacles other than 120 volt shall have GFCI protection. Standard 240 installed on 50 amp receptacle.
|
ELE19-00831
| Electrical Rough-In | 5/1/2019 | 5/2/2019 | 5/2/2019 11:22:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Listing and disconnecting means confirmed rough in ok
|
ELE19-00777
| Final | 5/1/2019 | 5/2/2019 | 5/2/2019 10:52:47 AM | A | FAIL |
|
|
garage code should be 0425 Phone #: ###-#### Inspection requested via web by Neal Rumsey 314.16- Boxes shall have adequate space for conductors installed. Island receptacle has 11.25 cubic inches of conductor installed in a 8 cubic inch box.
|
ELE19-01595
| Electrical Rough-In | 5/1/2019 | 5/2/2019 | 5/2/2019 9:44:12 AM | A | PASS |
|
|
Homeowner will be home in am. His name is Jeff Wirht. Phone #: ###-#### Inspection requested via web by Craig Korell Kitchen and laundry rough in k cover
|
ELE19-01540
| Electrical Rough-In | 4/30/2019 | 5/2/2019 | 5/2/2019 9:16:11 AM | A | PASS |
|
|
Contact Bruce Thorpe @ ###-#### with any questions
Thank you and have a nice day! Phone #: ###-#### Inspection requested via web by JENNY EMEL Wall rough in ok cover
|
ELE19-00817
| Electrical Rough-In | 5/1/2019 | 5/2/2019 | 5/2/2019 8:59:51 AM | A | PASS |
|
|
Ceiling inspection for cover Phil is the contact North Face Phone #: ###-#### Inspection requested via web by Shawna Gates Dressing rooms and entrance lids rough in ok cover
|