ELE11-00368
| ELE-Aging Inspection | 5/30/2013 | 5/30/2013 | 5/30/2013 3:56:53 PM | | DONE |
|
|
Still waiting on owner
|
ELE13-00393
| Final | 5/30/2013 | 5/30/2013 | 5/30/2013 3:28:06 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson Final ok
|
ELE13-01311
| Rough-In Permanent Service | 5/30/2013 | 5/30/2013 | 5/30/2013 2:52:23 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov 300.4- Protection from physical damage, washer, dryer, furnace wires plus misc through out. 250.110- Non current carrying metal parts shall be connected to equiptment grounding conductor. 300.3(C)- Conductors shall have an insulating rating equal to the maximum circuit voltage applied to any conductor with in enclosure.
|
ELE13-01361
| Electrical Rough-In | 5/30/2013 | 5/30/2013 | 5/30/2013 2:22:06 PM | P | PASS |
|
|
Please call 30 min prior to inspection. Phone #: ###-#### >> Inspection requested via web by Camille Gulley wall rough in ok cover
|
ELE13-00388
| Final | 5/30/2013 | 5/30/2013 | 5/30/2013 1:18:33 PM | P | NR |
|
|
Final on main level only. Thank you Phone #: ###-#### >> Inspection requested via web by Eric Brown Covers, labelling, wp inaccessible, not all breakers installed.
|
ELE13-01360
| Electrical Rough-In | 5/30/2013 | 5/30/2013 | 5/30/2013 12:34:31 PM | P | PASS |
|
|
CALL FOR ACCESS Phone #: ###-#### >> Inspection requested via web by John VanZandt Kitchen, misc lighting, and baths remodel rough in ok cover.
|
ELE13-01354
| Temporary Service | 5/29/2013 | 5/30/2013 | 5/30/2013 10:31:11 AM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman 250.24(A)- Grounding electrode conductor connection shall be made at the same terminal or bus as grounded conductor. 110.7- GFCI receptical on right has test button stuck in depressed state. Replace. Remove debris from mater base.
|
ELE13-01133
| Final | 5/29/2013 | 5/30/2013 | 5/30/2013 10:25:43 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey final ok
|
ELE13-00866
| Final | 5/29/2013 | 5/30/2013 | 5/30/2013 10:00:11 AM | A | PASS |
|
|
Call Jim (###-####) 30 min ahead for access Phone #: ###-#### >> Inspection requested via web by Brad Girard Final ok
|
ELE13-00609
| Final | 5/29/2013 | 5/30/2013 | 5/30/2013 9:45:34 AM | A | PASS |
|
|
Call Jim (###-####) 30 min ahead for access Phone #: ###-#### >> Inspection requested via web by Brad Girard Final ok
|
ELE12-02982
| Electrical Rough-In | 5/29/2013 | 5/30/2013 | 5/30/2013 9:22:08 AM | A | PASS |
|
|
Tony Phone #: ###-#### Ceiling pour noted on print rough in ok cover
|
ELE13-00977
| Final | 5/29/2013 | 5/30/2013 | 5/30/2013 8:52:25 AM | A | PASS |
|
|
Kevin Phone #: ###-#### Final ok
|
ELE13-01351
| Temporary Service | 5/29/2013 | 5/30/2013 | 5/29/2013 1:38:04 PM | A | PASS |
|
|
READY NOW Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE13-01352
| Temporary Service | 5/29/2013 | 5/30/2013 | 5/29/2013 1:36:33 PM | A | PASS |
|
|
READY NOW Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
|