Inspections for the day of: Wednesday, June 12, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-00642 ELE-Aging Inspection6/12/20196/12/20196/12/2019 3:23:04 PM FAIL
Waiting for contractor to reschedule
ELE19-02145 Final6/12/20196/12/20196/12/2019 3:19:33 PMPPASS
Final ok
ELE19-02145 Electrical Rough-In6/12/20196/12/20196/12/2019 3:18:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Dean Gernaat
No electrical in demizing wall. Emergency/exit tested OK. Demizing wall rough in ok cover.
ELE19-02144 Electrical Rough-In6/12/20196/12/20196/12/2019 3:17:16 PMPPASS
Exit sign only, possible final? Phone #: ###-#### Inspection requested via web by Dean Gernaat
No electrical in demizing wall. Emergency/exit tested OK. Demizing wall rough in ok cover.
ELE19-02144 Final6/12/20196/12/20196/12/2019 3:16:50 PMPPASS
Exit sign only, possible final? Phone #: ###-#### Inspection requested via web by Dean Gernaat Final ok
ELE19-02063 Electrical Rough-In6/11/20196/12/20196/12/2019 2:52:56 PMPPASS
Electrical Underground Inspection
Please call mike at number listed for entry into plant. Phone #: ###-#### Inspection requested via web by Tye Thomas
Area of classification from east side of jet filter pad to west class 1 div 2, east of jet filter pad unclassified. Underground from transformer to east side of jet filter pad rough in ok cover
ELE19-00609 Final6/11/20196/12/20196/12/2019 2:07:07 PMPPASS
Final out slab work. Phone #: ###-#### Inspection requested via web by Tom Betty
Final ok on foundation and underground.
ELE19-01406 Electrical Rough-In6/11/20196/12/20196/12/2019 2:06:22 PMPPASS
Fire lid/top out level 1 area B units rough in. Phone #: ###-#### Inspection requested via web by Tom Betty
No longer marking contractor print.
Area noted except laundry and shipping fire lids and top out walls rough in ok cover.
ELE19-01730 Electrical Rough-In6/12/20196/12/20196/12/2019 11:01:53 AMAPASS
Underground inspection
Contact Alex Ybarra
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Located on north west corner of 11th and Idaho underground rough in ok cover.
ELE19-02079 Rough-In Permanent Service6/11/20196/12/20196/12/2019 9:54:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE19-02078 Rough-In Permanent Service6/11/20196/12/20196/12/2019 9:54:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE19-02133 Rough-In Permanent Service6/11/20196/12/20196/12/2019 9:00:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Mike Okamura
Undergound rough in ok if home is positioned with in 4' of pedistal. Conduit covered prior to enspection. Appears to heve depth if close to pedistal. p/s u/g n ok
ELE19-02120 Rough-In Permanent Service6/11/20196/12/20196/12/2019 8:28:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Heath Thomas
Rough in ok cover p/s u/g n ok