Inspections for the day of: Tuesday, June 18, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02244 Electrical Rough-In6/18/20196/18/20196/18/2019 2:40:25 PMPPASS
Underground to cover conduits Phone #: ###-#### Inspection requested via web by Stan Woodward
Underground rough in ok cover
ELE19-01604 Electrical Rough-In6/18/20196/18/20196/18/2019 2:20:00 PMPPASS
Pony wall Phone #: ###-#### Inspection requested via web by Bryan McLaughlin
Area noted rough in ok cover
ELE19-00602 Electrical Rough-In6/18/20196/18/20196/18/2019 1:58:53 PMPPASS
Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
EMT being used with taped up boxes and fittings as per instructions. Bottom of ramp pour rough in ok cover
ELE19-00433 Final6/18/20196/18/20196/18/2019 1:47:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Mike McCarrel
Bldg E-1 Hornbill exibit final ok
ELE19-00881 Permanent Service6/17/20196/18/20196/18/2019 12:08:11 PMAFAIL
Please call before you head to the site Phone #: ###-#### Inspection requested via web by Spencer McLean
408.7- Unused breaker spaces shall be closed by approved means. Breaker blank needed.
ELE19-02222 Final6/17/20196/18/20196/18/2019 11:50:19 AMAPASS
Home owner should be home. Panel is on back of house. A/c is on west side Phone #: ###-#### Inspection requested via web by Jake Cutler
Final ok
ELE19-01028 Permanent Service6/17/20196/18/20196/18/2019 11:30:36 AMACANC
Please call before heading to the site. Phone #: ###-#### Inspection requested via web by Spencer McLean
Needed final inspection.
ELE19-01028 Final6/18/20196/18/20196/18/2019 11:30:26 AMPFAIL
Please call before heading to the site. Phone #: ###-#### Inspection requested via web by Spencer McLean
408.7- Unused breaker spaces shall be closed by approved means. Breaker blank needed in panel at base of pole.
ELE19-00594 Final6/17/20196/18/20196/18/2019 11:18:23 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn
110.3- Devices shall be wired as per manufacturers instructions. Reverse polarity in laundry.
210.8(A)(2)- Unfinished space off garage receptacles shall have GFCI protection.
314.16- Boxes shall have sufficient subic inch rating for conductors installed. Island receptacle box 8 cubic inches with 11.25 of conductor cubic inch installed.
348.30- FMC shall be secured with in 12" of a termination. Furnace, disposal.
406.5- Master bed USB receptacle shall be flush or project from face plate.
ELE19-01635 Final6/17/20196/18/20196/18/2019 10:28:23 AMAFAIL
Phone #: ###-#### Inspection requested via web by Steven Ragan
358.42- Couplings and connectors shall be made tight. Several loose.
ELE19-01453 Final6/17/20196/18/20196/18/2019 10:12:12 AMAPASS
thr key code is 4040 Thanks Phone #: ###-#### Inspection requested via web by brian morrow Final ok