ELE19-01948
| Electrical Rough-In | 6/4/2019 | 6/4/2019 | 6/4/2019 2:40:34 PM | P | PASS |
|
|
Access is limited. Please call Jason when you arrive in the lobby. ###-#### Phone #: ###-#### Inspection requested via web by Jason Parke North and east walls as noted on contractor print rough in ok cover.
|
ELE18-02369
| Final | 6/3/2019 | 6/4/2019 | 6/4/2019 2:17:25 PM | P | PASS |
|
|
Call Joey C. prior to arrival. Phone #: ###-#### Inspection requested via web by Scott Campbell Final ok
|
ELE19-00003
| Final | 6/4/2019 | 6/4/2019 | 6/4/2019 12:56:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terry Scott Final ok
|
ELE19-02027
| Temporary Service | 6/4/2019 | 6/4/2019 | 6/4/2019 11:39:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Shaun Kirkman t/s o/h n ok
|
ELE19-00645
| Final | 6/3/2019 | 6/4/2019 | 6/4/2019 10:42:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga 410.16- Incandescent and LED luminaires shall not be installled with in 12" of a sorage shelf in a clothes closet. Up bed. * Fee due- Fee charged was for service only, additional $80 due for dwelling totalling $135.
|
ELE19-00646
| Final | 6/3/2019 | 6/4/2019 | 6/4/2019 10:40:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga 210.8- All 15 or 20 amp 120 volt receptacle outets installed with in 6' of a sink shall have GFCI protection. Washer. 210.52(A)- No point measured along floor line shall be more than 6' from a receptacle outlet. Dining area. 210.70- A luminaire shall be installed on the exterior of each doorway with exterior access. Garage mandoor. 410.16- Incandescent and LED luminaires shall not be installed with in 12" of storage shelf in a clothes closet. * Fee due- Fee charged was for service only, additional $80 due for dwelling totalling $135.
|
ELE19-02019
| Electrical Rough-In | 6/3/2019 | 6/4/2019 | 6/4/2019 9:49:30 AM | A | PASS |
|
|
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden BCC 4-05-32 No code violation shall be retained. 394.12- Knob and tube wiring shall not be surrounded by thermo-insulation in attic. Kitchen remodel rough in ok cover.
|
ELE18-01935
| Electrical Rough-In | 6/3/2019 | 6/4/2019 | 6/4/2019 9:17:22 AM | A | PASS |
|
|
4th floor hall drop ceiling rough-in for cover. Contact John (Homey) McElroy Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Area noted rough in ok cover.
|