ELE19-02588
| Permanent Service | 7/12/2019 | 7/12/2019 | 7/12/2019 2:37:36 PM | P | NH |
|
|
Space is been empty for three or four years need to get inspection so meter can be set. Please call Nicole with Colliers in advance. 208 -###-####. Located in Hampton in building south of parking garage entry. Please call with any questions Phone #: ###-#### Inspection requested via web by Rex Boyles Called Nicole 20 minutes prior to arrival, no answer, left message, door locked, contractor directed me to electrical room which was also locked. Will recall when accessible.
|
ELE19-02574
| Electrical Rough-In | 7/11/2019 | 7/12/2019 | 7/12/2019 1:59:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by sam petterson Addition to front and rear of garage with rewire old garage area. Rough in ok cover
|
ELE19-02556
| Rough-In Permanent Service | 7/10/2019 | 7/12/2019 | 7/12/2019 1:17:51 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g rec ok
|
ELE19-01804
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 12:49:46 PM | A | PASS |
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
ELE19-01527
| Final | 7/12/2019 | 7/12/2019 | 7/12/2019 11:56:38 AM | P | FAIL |
|
|
garage code 7530 Phone #: ###-#### Inspection requested via web by Darryn Coburn 110.3- Devices shall be wired as per manufacturers instructions. Christmas GFCI will not set, Bath GFCI hot load is not hot. 110.7- Finished product shall be free of short circuits. Garage circuit breaker trips when GFCI is set. 314.25- All boxes shall have covers. Up niche light box open.
|
ELE19-01199
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 11:52:21 AM | A | PASS |
|
|
garage code 7530 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
ELE19-02573
| Conference | 7/11/2019 | 7/12/2019 | 7/12/2019 10:20:40 AM | A | PASS |
|
|
Scott Phone #: ###-#### Discussed refeeding existing AC unit from existing disconnect underground. concrete will cover this area, sch 80, depth, conductors. pamphlet given
|
ELE19-01406
| Electrical Rough-In | 7/11/2019 | 7/12/2019 | 7/12/2019 9:29:16 AM | A | PASS |
|
|
4 level 1 kitchen pony walls and level 1 area B lids. Phone #: ###-#### Inspection requested via web by Tom Betty Level 1 area B not ready. Kitchen and breakroom changes in walls rough in ok cover
|
ELE19-01604
| Final | 7/12/2019 | 7/12/2019 | 7/12/2019 9:09:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin Final ok
|
ELE19-01317
| Final | 7/11/2019 | 7/12/2019 | 7/12/2019 8:52:02 AM | A | PASS |
|
|
Contact: Ryan Mrachek Phone #: ###-#### Inspection requested via web by Deb Gooden Final ok
|