ELE13-01329
| ELE-Aging Inspection | 7/15/2016 | 7/15/2016 | 7/15/2016 3:04:01 PM | | CANC |
|
|
|
ELE10-00275
| ELE-Aging Inspection | 7/15/2016 | 7/15/2016 | 7/15/2016 3:03:42 PM | | CANC |
|
|
|
ELE10-00196
| ELE-Aging Inspection | 7/15/2016 | 7/15/2016 | 7/15/2016 3:03:35 PM | | CANC |
|
|
|
ELE16-02264
| Electrical Rough-In | 7/15/2016 | 7/15/2016 | 7/15/2016 3:02:59 PM | P | PASS |
|
|
Bathroom wire Phone #: ###-#### Inspection requested via web by Greg Idsinga Bathroom walls and hardlid rough in ok cover
|
ELE16-02161
| Electrical Rough-In | 7/15/2016 | 7/15/2016 | 7/15/2016 2:39:29 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank You! Phone #: ###-#### Inspection requested via web by Clay Morgan Called to attach to BLD16-01557. Unit 2277 rough in ok cover
|
ELE16-02160
| Electrical Rough-In | 7/15/2016 | 7/15/2016 | 7/15/2016 2:39:12 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank You! Phone #: ###-#### Inspection requested via web by Clay Morgan Called to attach to BLD16-01557. Unit 2275 rough in ok cover
|
ELE15-03901
| Electrical Rough-In | 7/15/2016 | 7/15/2016 | 7/15/2016 2:10:33 PM | P | PASS |
|
|
Call for r/i inspection of cabinet wall on 8th floor east break room. Phone #: ###-#### Inspection requested via web by Rafael Castillo As noted rough in ok cover
|
ELE15-01617
| Electrical Rough-In | 7/14/2016 | 7/15/2016 | 7/15/2016 1:19:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Underground in planters in south parking lot rough in ok cover
|
ELE15-02740
| Conference | 7/15/2016 | 7/15/2016 | 7/15/2016 12:52:50 PM | P | DONE |
|
|
Thac Phone #: ###-####090 Discusses the access to disconnecting means of HVAC equipment and duct heaters. As per Daryl DeGrange need 24" deep if possible in no case access be less than 18".
|
ELE16-01667
| Conference | 7/14/2016 | 7/15/2016 | 7/15/2016 11:09:26 AM | A | PASS |
|
|
Discuss use of romex in all condo''s with Craig Phone #: ###-#### Inspection requested via web by Tom Betty Discussed use of NM cable in condos. Building permit noted type V construction. NM cable shall have at least 15 minute fire barrier and not be installed above drop or grid ceilings as per NEC 334.10. Also mentioned access to HVAC unit control boxes shall have room to access.
|
ELE16-01964
| Final | 7/14/2016 | 7/15/2016 | 7/15/2016 10:09:38 AM | A | PASS |
|
|
Swimming Pool - Shon Phone #: ###-#### Corrections made. Final ok
|
ELE16-01846
| Final | 7/14/2016 | 7/15/2016 | 7/15/2016 9:32:18 AM | A | PASS |
|
|
If you have any questions please call Mike ###-#### Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
|
ELE16-02256
| Electrical Rough-In | 7/14/2016 | 7/15/2016 | 7/15/2016 9:13:46 AM | A | PASS |
|
|
Brandon is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce 11 of 14 west, south and east pole bases. Underground installed prior to inspection. All U/G under sidewalk and planter areas. rough in ok cover
|
ELE16-01867
| Final | 7/14/2016 | 7/15/2016 | 7/15/2016 8:59:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tracy Robertson As per Daryl Degrange show window receptacles OK'd above 18" at rough in stage. Final ok
|