Inspections for the day of: Tuesday, July 16, 2019.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-04106 Electrical Rough-In7/15/20197/16/20197/16/2019 2:40:56 PMPFAIL
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
BLD must be issued proir to any electrical inspection.
300.15- All cables and conduits shall terminate in a box. Wiring left hanging where old sign had been removed.
ELE18-01929 Permanent Service7/16/20197/16/20197/16/2019 2:11:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s o/h rec ok
ELE19-00602 Electrical Rough-In7/15/20197/16/20197/16/2019 1:42:32 PMPPASS
Garage concrete pour cover. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
Report has been given of someone with general contractor removing electrical conduits with out informing electrical contractor.
BCC 4-05-15 It shall be unlawful for any person to engage in electrical work without first having a electrical journeymans license and be employed by an electrical licenced and permitted electrical contractor.
First and only warning, if any electrical wiring , conduit, or equipment is installed or removed without consulting electrical foreman of licensed and permitted electrical contractor a compliance inspector from the State of Idaho will be brought on site to discuss penalties and fines up to $1000 that may be assessed for each infraction. Level 2 west pour as noted on contractor print rough in ok cover
ELE19-01669 Electrical Rough-In7/15/20197/16/20197/16/2019 11:51:22 AMAPASS
electrical rough in Phone #: ###-#### Inspection requested via web by Tim Dunlop 250.53- A single ground rod shall have a suppemental rod installed unless proven less that 25ohms to ground by final.
#8 SER 40amp max installed for range circuit.
Rough in ok cover
ELE19-02621 Electrical Rough-In7/15/20197/16/20197/16/2019 11:09:25 AMANR
Rough in inspection and consult with a few questions regarding job. Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
Rough in not ready
Discussed removing subfeed from house to garage due to equipment ground must be added and small conduit between. Metal underground water pipe from house to garage must be added to grounding electrode system. Up bath does not have a basin in stool room so dedicated circuit not required. If clothes rod present in closet then AFCI protection required upstairs.
Contractor believes he will pull sub feed to panel in garage from service mounted on garage eliminating most code issues.
ELE19-01406 Electrical Rough-In7/15/20197/16/20197/16/2019 10:12:40 AMAPASS
Level 1 area B ceilings and walls. Phone #: ###-#### Inspection requested via web by Tom Betty Area B except 104, 105, 106, 118, 119, 122, 124, 162. Rest of walls and hardlids rough in ok cover
ELE18-01935 Electrical Rough-In7/15/20197/16/20197/16/2019 9:37:49 AMAPASS
North Half - 5th Floor Hall Ceiling Inspection
Contact electrician John (Homey) McElroy
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
North and south corridor ceiling to center stair rough in ok cover