Inspections for the day of: Wednesday, July 17, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-00899 ELE-Aging Inspection7/17/20197/17/20197/17/2019 3:08:14 PM PASS
Doc final, job cancelled
ELE17-00899 DOC - Permit Expired7/17/20197/17/20197/17/2019 3:07:30 PMPPASS
Doc final ok Job cancelled
ELE19-00601 Electrical Rough-In7/17/20197/17/20197/17/2019 3:04:29 PMPPASS
Concrete cover on PT deck. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
Level 2 PT deck pour rough in ok cover
ELE19-01730 Final7/17/20197/17/20197/17/2019 1:28:52 PMPPASS
Contact Alex Ybarra
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
ELE19-01282 Final7/16/20197/17/20197/17/2019 12:48:26 PMAPASS
Hello, this is for the First Interstate Banks 4 new illuminated wall signs.
Please contact the manager for access to electrical room and permits.
Please call Mark Myers if have any concerns at ###-####.
Thank you, Ardis @ Carlson Sign Co. Phone #: ###-#### Inspection requested via web by Ardis Cox Final ok
ELE19-01282 Electrical Rough-In7/17/20197/17/20197/17/2019 12:48:04 PMPPASS
Listing and disconnecting means confirmed. Rough in ok cover
ELE19-01093 Final7/16/20197/17/20197/17/2019 12:17:03 PMAPASS
Hello!
This is for the new wall signs at the new First Interstate Bank. Please contact the manager to give you access to the electrical room. If you have any questions or concerns please call Mark Myers at ###-####. Thank you,
Ardis @ Carlson Sign Co. Phone #: ###-#### Inspection requested via web by Ardis Cox
Final ok
ELE19-01093 Electrical Rough-In7/17/20197/17/20197/17/2019 12:16:36 PMPPASS
Hello!
This is for the new wall signs at the new First Interstate Bank. Please contact the manager to give you access to the electrical room. If you have any questions or concerns please call Mark Myers at ###-####. Thank you,
Ardis @ Carlson Sign Co. Phone #: ###-#### Inspection requested via web by Ardis Cox Listing and disconnecting means confirmed. Rough in ok
ELE19-02523 Rough-In Permanent Service7/16/20197/17/20197/17/2019 11:18:12 AMAFAIL
Phone #: ###-#### Inspection requested via web by Barbara Szurgot
110.14(D)- Grounding electrode termination in meter panel combo shall be torqued to spec. Termination in panel loose.
210.52(C)- Area to right of range is new counter top space in kitchen and shall have receptacle outlets installed.
250.110- Short runs of flexible metal conduit shall be bonded to equiment grounding conductor or terminate to a box with equipment grounding conductor terminated within. Floor heat boxes.
300.4- Where NM cable is run thru holes or channels that do not maintain 1 1/4" from framing surface they shall be protected from physical damage by nail plates or raceways.
408.7- Unused breaker spaces shall be closed by approved means prior to being energized.
ELE19-02403 Electrical Rough-In7/17/20197/17/20197/17/2019 9:34:28 AMAPASS
For access please all Troy 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Stage floor receptacles shall be seperate due to listing of low volt not listed for line voltage.
Sound booth and stage floor and walls rough in ok cover
ELE19-01730 Final7/16/20197/17/20197/17/2019 7:21:43 AMACANC
Contact Alex Ybarra
Thank you Phone #: ###-#### >> Inspection requested via web by Cathy Duchek Inspection cancelled from web by: Cathy Duchek
ELE19-01018 Electrical Rough-In7/16/20197/17/20197/16/2019 1:24:30 PMAPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
East underground for 6 lights rough in ok cover