Inspections for the day of: Tuesday, September 10, 2019.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-03395 Temporary Service9/10/20199/10/20199/10/2019 4:44:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Cevyn Recla t/s u/g n ok
ELE19-03050 Electrical Rough-In9/10/20199/10/20199/10/2019 4:12:13 PMPPASS
We should be on site however please call in advance to just make sure we are there and can walk you through. Phone #: ###-#### Inspection requested via web by Casey Fouts
Master floor heat rough in ok cover
ELE19-03380 Conference9/9/20199/10/20199/10/2019 3:25:19 PMPDONE
call for access- Justin Phone #: ###-#### Due to city ordinance and complaint 240 volt circuit located in basement must be removed and rendered unusable. Informed owner wire must be cut off where enters and panel and range box in basement. Call for inspection to verify and issue will be done.
ELE19-03312 Final9/5/20199/10/20199/10/2019 3:00:09 PMPFAIL
Apartment 201, top left. Compressor is on the north side of the building, right behind the Left Hand garage. The breaker panel is inside the apartment on an interior wall, so we ran 12/2 NM up into the attic and over to a j-box that''s on the end of EMT stubbed in from outside, and #12 wires from there down the outside of the bldg to the local disconnect. Phone #: ###-#### Inspection requested via web by Dan Hilke
300.10-This is for HVAC coated MC termination. MC shall terminate in KO with an approved connector listed for cable used.
No answer at door to confirm 20 amp overcurrent device.
ELE19-03174 Electrical Rough-In9/10/20199/10/20199/10/2019 2:36:19 PMPPASS
Please call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez
Back kitchen wall, office and closet to right walls and hardlid, S.W. corner lid rough in ok cover.
ELE19-02151 Final9/10/20199/10/20199/10/2019 2:02:41 PMPNH
Phone #: ###-#### Inspection requested via web by John VanZandt
Unit locked, contractor will call in when accessible.
ELE19-02492 Electrical Rough-In9/10/20199/10/20199/10/2019 1:46:07 PMPPASS
Phone #: ###-#### Inspection requested via web by Nick Smith
Discussed GFCI protection, Tamper resistant, NM supports not to exceed 4 1/2', 60 amp minimum feed to garage with more than 2 circuits. Wiring ran on surface of upper plates and down side of studs to boxes. Explained all below 8' needs guard strips to protect from physical damage.
Rough in ok.
ELE19-00991 Final9/10/20199/10/20199/10/2019 1:16:29 PMPFAIL
2010 Phone #: ###-#### Inspection requested via web by danny perrine
110.3- Devices shall be wired as per manufacturers instructions. Dine, island, master hall 3-ways mis-wire. One switch locks out other. Kitchen GFCI near sink will not hold. Dining receptacle to left of kitchen sink counter show hot gr. reversed.
410.16- Luminaires located in closet shall not have open bulbs. master closet.
ELE18-01935 Final9/9/20199/10/20199/10/2019 11:45:26 AMAPART
Final for Units 311, 312, 313, 314, and 315.
Contact John (Homey) McElroy.
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Units noted signed off in offce. TCO ok
ELE19-03260 Final9/9/20199/10/20199/10/2019 10:43:13 AMAPASS
The homeowner will be notified to have garage access. Phone #: ###-#### Inspection requested via web by Ashley Lanham
Final ok
ELE19-01973 Final9/9/20199/10/20199/10/2019 10:12:01 AMAFAIL
IF it is locked there is a lock box in the 4 plex 9351 lock on the hand rail the code is 3600 Phone #: ###-#### Inspection requested via web by Neal Rumsey
300.10- Metellic raceways shall terminate in a box. Exposed conductors from flex connector to box with out sheathing in islands.
* Access being added to each side. At time of inspection wiring visible from hole open. Wiring shall be protected from damage as per 320.23.
ELE19-01427 Final9/9/20199/10/20199/10/2019 9:35:22 AMANH
Please contact when in route as no one is on site. Phone #: ###-#### Inspection requested via web by Cortney Hopper
Called contact, no answer, left message. Due to being very short handed unable to wait around. Must recall.
ELE19-00689 ELE-Request for Extension9/9/20199/10/20199/10/2019 9:15:08 AMAPASS
Call ahead // Tim Phone #: ###-####
Just slow moving job. Extension ok.
ELE19-02176 Final9/9/20199/10/20199/10/2019 9:12:19 AMAPASS
electrical final at idaho Power. 9AM please call Phil 1 hour before so he can have a escort set up. Phone #: ###-#### Inspection requested via web by Deb Ipsen
Occupancy card signed. Final ok
ELE19-03358 Rough-In Permanent Service9/9/20199/10/20199/10/2019 8:34:29 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson
Rough in ok cover p/s u/g n ok