Inspections for the day of: Wednesday, September 30, 2015.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-03141 Electrical Rough-In9/30/20159/30/20159/30/2015 3:19:58 PMPPASS
rough in lighting retrofit Phone #: ###-#### Inspection requested via web by Tim Dunlop Listing confirmed. Rough in ok
ELE15-03141 Final9/30/20159/30/20159/30/2015 2:54:51 PMPPASS
rough in lighting retrofit Phone #: ###-#### Inspection requested via web by Tim Dunlop Final ok
ELE13-01178 Final9/30/20159/30/20159/30/2015 2:34:21 PMPPASS
sign final ok
ELE13-01708 Final9/30/20159/30/20159/30/2015 2:10:56 PMPPASS
UL listing confirmed. Final ok
ELE15-03041 Electrical Rough-In9/30/20159/30/20159/30/2015 2:09:51 PMPPASS
Scott. Ceiling cover in consultation room. Phone #: ###-#### Inspection requested via web by Sean DeLacy Scheduled a return trip 10-1 to check temp power outlet for drinking fountain with out a cover. Grid rough in ok cover
ELE15-02347 Final9/30/20159/30/20159/30/2015 1:39:16 PMPFAIL
Joe Phone #: ###-#### - call 30 mins prior to meet 680.21(C)- 240 volt pump circuits shall have GFCI protection. Existing hot tub does not have GFCI protection.
4-05-32- Code violations not to be retained
ELE15-03143 Rough-In Permanent Service9/30/20159/30/20159/30/2015 1:13:05 PMPPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
ELE15-02334 Final9/30/20159/30/20159/30/2015 12:30:53 PMPPASS
Back man door to garage is unlocked. Phone #: ###-#### Inspection requested via web by Kotton Corder Final ok
ELE15-03117 Electrical Rough-In9/29/20159/30/20159/30/2015 10:41:57 AMAPASS
Grounding Inspection, Chad Van Orden is contact. ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Concrete encased electrode rough in ok cover
ELE15-02984 Final9/29/20159/30/20159/30/2015 10:23:33 AMAPASS
Phone #: ###-#### Inspection requested via web by kendall bender Final ok
ELE15-02933 Permanent Service9/30/20159/30/20159/30/2015 9:56:50 AMPCANC
MIKE COLE Phone #: ###-#### Inspection requested via web by mike brown Asked to cancel due to Idaho Power not able to turn off power until very late morning. Rescheduled for next day
ELE15-03069 Electrical Rough-In9/29/20159/30/20159/30/2015 9:54:57 AMAPASS
Adam Phone #: ###-#### Interior entry and exterior rough in ok cover
ELE15-03130 Rough-In Permanent Service9/29/20159/30/20159/30/2015 9:35:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Richard Gratiot 590.6(B)- All temp power shall have GFCI protection. 50 amp breaker did not trip when tested. Called contractor. Rough in ok cover p/s u/g n ok
ELE15-02984 Final9/29/20159/30/20159/29/2015 4:23:46 PMPCANC
Phone #: ###-#### >> Inspection requested via web by kendall bender Inspection cancelled from web by: kendall bender